Fujitsu MB2147-01 User Port Power Supply Switching, Operating The Emulator, User system, source

Models: MB2147-01

1 66
Download 66 pages 54.19 Kb
Page 54
Image 54
3.4User Port Power Supply Switching

CHAPTER 3 OPERATING THE EMULATOR

3.4User Port Power Supply Switching

Select a user port power supply for the evaluation MCU.

Switching of the user port power supply

■Switching of the user port power supplyUser systemVCC SEL settingCAUTION

Make sure that power to the product is turned off and the power plug is

Prohibition disconnected from outlets before handling jumpers. Doing so may result in device problems or electric shock.

On the emulator, use the jumper for switching the user port power supply to set the reference voltage of the user data bus probing circuit.

The user data bus for which the reference voltage is set corresponds to user ports 0 and 1. Set the user port reference voltage for each port power supply source.

For details on the user data bus probing circuit, see Section 3.6 "User Data Bus Switching."

UVCC1: Main power supply for the evaluation MCU

UVCC2: Secondary power supply for the evaluation MCU

Table 3.4-1"Settings of the jumper for switching the user port power supply" lists settings of the jumper for switching the user port power supply.

Table 3.4-1 Settings of the jumper for switching the user port power supply

User system

 

 

VCC SEL setting

 

 

 

 

 

power supply

Jumper for selecting user port 0 power

Jumper for selecting user port 1 power

source

supply (P0V)(*1)

supply (P1V)(*1)

Single source

A connected to B (UVCC1 setting)

A connected to B (UVCC1 setting)

 

 

Jumper connection on target power supply

Jumper connection on target power supply

Dual source

 

side(*2)

 

side(*2)

 

 

A connected to B

B connected to C

A connected to B

B connected to C

 

 

 

 

(UVCC1 setting)

(UVCC2 setting)

(UVCC1 setting)

(UVCC2 setting)

*1: See Figure 3.3-1"Emulator-dedicated power supply switching jumper" for positions of the jumper for switching the user port power supply.

*2: Set a jumper connection to select the VCC that corresponds to a user port power supply.

Example: User port 0 power supply is UVCC1, and user port 1 power supply is UVCC2:

Jumper for selecting user port 0 power supply (P0V): Connect A to B (UVCC1 setting).

Jumper for selecting user port 1 power supply (P1V): Connect B to C (UVCC2 setting).

40

Page 54
Image 54
Fujitsu MB2147-01 manual User Port Power Supply Switching, Operating The Emulator, Switching of the user port power supply