SK-96370-144PMC-GDC User Guide

Chapter 3 Jumpers and Switches

3.9LIN / UART

There are two identical circuit blocks for LIN or RS232 connections. Each of the two D-Sub connectors can be configured as LIN or RS232 interface. DTS or RTS can be selected as reset source, and RTS and CTS can be connected by a jumper, since some terminals and Flash programming tools need this connection. Pin 1 (Vs) of X5 and X9 can be connected to the voltage input of the board by jumpers in order to supply the LIN bus.

3.9.1 LIN-UART 0 (JP: 19, 21, 23, 25, 27, 28, 29, 31)

 

Jumper

 

Setting

 

 

Description

 

 

 

 

 

 

 

 

 

 

JP21

1-2

 

 

SIN0 is connected to RS232 transceiver

 

(RXD)

2-3

 

 

SIN0 is connected to LIN transceiver

 

 

 

 

 

 

 

JP25

 

1-2

 

 

SOT0 is connected to RS232 transceiver

 

 

(TXD)

2-3

 

 

SOT0 is connected to LIN transceiver

 

JP27

 

1-2

 

 

X5 pin 2 is connected to RS232 transceiver

 

 

(RS232/LIN)

2-3

 

 

X5 pin 2 is connected to LIN transceiver

 

 

 

 

 

 

 

 

 

 

 

 

JP19

 

Closed

 

 

RTS and CTS of X5 are connected

 

 

(RTS-CTS)

 

Open

 

 

RTS and CTS of X5 are not connected

 

 

 

 

 

 

 

 

 

 

 

 

JP23

1-2

 

 

DTR signal (pin 6 of X5) is used as reset source

 

(DTR/RTS)

2-3

 

 

RTS signal (pin 7 of X5) is used as reset source

 

 

 

 

 

 

 

 

 

 

 

 

JP29

 

Closed

 

 

LIN transceiver is enabled

 

(LIN enable)

 

Open

 

 

LIN transceiver is disabled

 

 

 

 

 

 

JP31

 

Closed

 

 

LIN-UART0 is LIN Master

 

(LIN master)

 

Open

 

 

LIN-UART0 is LIN Slave

 

 

 

 

 

 

 

 

JP28

 

Closed

 

 

LIN bus (X5 pin 1) is powered by the board

 

(LIN Vbat)

 

Open

 

 

LIN bus (X5 pin 1) is not powered by the board

 

 

 

 

 

 

 

 

 

 

 

Table 3-7: UART0 Settings