Chapter 3 Jumpers and Switches
3.13 Graphic Display Controller interface (JP: 54, 55, 56, 57, 58, 60, 85, 86)
The
Take care of proper jumper settings, in case those external
JP54 Address line A24 is not supported by the microcontroller
JP55 Address line A25 is not supported by the microcontroller
JP56 | Signal sharing of A22 and CS2 for FLASH and GDC | 3 |
| |
4 | 2 | |||
JP57 | Chip selection for external sub board | |||
|
|
JP58 1.8V power supply
JP60 Mains power supply
JP70, 71 The port P08_0 may be used e.g. to generate manual reset on the sub board.
| Jumper | Setting |
|
| Description |
| JP54 | Open |
| Address line A24 is floating | |
| (A24) |
|
|
| |
| Closed |
|
| Address line A24 is connected to GND | |
| JP55 | Open |
| Address line A25 is floating | |
| (A25) |
|
|
| |
| Closed |
| Address line A25 is connected to GND | ||
| JP56 |
|
| Address line A22 is connected to the FLASH | |
| (GDC/FLASH) |
|
| CS2 is connected to the connector (see jumper JP57), too | |
|
|
| Address A22 of FLASH is connected to GND | ||
|
|
|
| ||
|
|
|
|
|
|
| JP57 |
|
| Connect CS3 to the connector | |
| (CS2/CS3) |
|
|
|
|
|
|
| Connect CS2 to the connector | ||
|
|
|
|
| |
| JP58 | Open |
| 1.8V is not supplied to connector X11B | |
| (1V8) |
|
|
| |
| Closed |
| 1.8V is supplied to connector X11B | ||
| JP60 | Open |
|
| Mains is not connected to connector X11B |
| (Mains) | Closed |
| Mains is connected to X11B | |
|
|
|
|
| |
| JP70 | Open |
| P08_0 is not connected to X11A_11A | |
| (GLRST) |
|
|
| |
| Closed |
| P08_0 is connected to X11A_11A | ||
| JP71 | Open |
| P08_0 is not connected to X11A_12A | |
| (FLRST) |
|
|
| |
| Closed |
| P08_0 is connected to X11A_12A | ||
|
|
|
|
|
|
Table 3-12: Graphic Display Controller interface