SK-96370-144PMC-GDC User Guide

Chapter 4 Connectors

4.5USER-LEDs & optional LC-Display (J1)

Eight LEDs are supplied for user applications. In order to disconnect the LEDs from the related microcontroller port (Port P09), the resistor network RN1 can be removed.

Instead of the user-LEDs, an alphanumeric LC-Display (optional) can be connected to J1.

The potentiometer RP1 can be used to adjust the contrast of the LC-Display. Pin 15 and 16 of J1 are normally not mounted. If the used LC-Display has pins for LED backlight at this position, they can be connected here (Pin15: Vcc via 39S/0.5W, Pin16: GND).

The contrast of an optional LC-Display connected to J1 can be adjusted by RP1. The following control signals are provided:

Figure 4-4: User LEDs/LCD

 

15*1

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14*

LCD

LCD

GND

GND

VCC

V0

RS

R/W

E

-

-

-

-

DB4

DB5

DB6

DB7

LED

LED

-

-

-

-

-

LD1

LD2

LD3

LD4

-

-

-

LD5

LD6

LD7

LD8

Port

-

-

-

-

-

09_0

09_1

09_2

09_3

-

-

-

09_4

09_5

09_6

09_7

Table 4-3: User LEDs/LCD

*1 Pin 15: Vcc via 39S/0.5W for LCD backlight

FMEMCU-UG-960014-10

- 26 -

© Fujitsu Microelectronics Europe GmbH

Page 26
Image 26
Fujitsu MB96300 manual USER-LEDs & optional LC-Display J1, User LEDs/LCD