Fujitsu MB96300 manual Installation, Connection/Power-On

Models: MB96300

1 36
Download 36 pages 24.25 Kb
Page 10
Image 10

SK-96370-144PMC-GDC User Guide

Chapter 2 Installation

2 Installation

2.1Connection/Power-On

Carefully remove the board from the shipping carton.

First, check if there are any damages before powering up the evaluation board.

For the power supply a DC input voltage of 9V – 15V is recommended. The positive voltage (+) must be connected to the center pin, and ground (GND) must be connected to the shield of the connector X7!

After power-on (Switch S2 or JP22), the red power-on LEDs (LD9, LD10, LD11, and LD12) should be lit. If the LEDs do not light up, switch off the power supply and check input polarity and current capability of the DC supply used. Please do not look directly into the LEDs to prevent harming your eyes.

The in-circuit programming allows the user to program own applications into the Flash memory. The procedures for Flash programming are described in chapter 5.

If the board shall be used as an emulator target board, switch off the power supply and remove the microcontroller from the socket. Now the probe cable can be mounted on the socket. Take care of the pin 1 marking on the socket and fasten the probe cable with the provided screws.

Do not use any other probe cable than MB2198-507-E only!

Connect the probe cable to the MB2198-500 emulation Adapter Board. Check all jumper settings of the evaluation board, the Probe Cable, and the Adapter Board.

When turning on the system, be sure to use the following power-up sequence:

1.Power up the Emulator Main Unit (MB2198-01)

2.Power up the Adapter Board (MB2198-500), if needed

3.Power up the target Board (SK-96370-144PMC-GDC)

To turn off the system, switch off the components in reverse order, beginning with the target Board.

Please refer to the corresponding user manuals and application notes for the emulator how to set up the emulator system. After power on the ‘UVCC’-LED of the emulator must be on.

Note:

Some customers experience connectivity problems when connecting the MCU into the socket adapter. Only the small red screwdriver available in your box should be used to connect the cover (HQPACK) onto the socket (NQPACK).

If the four screws are not tightening equally, then it may cause a poor contact.

Do not screw the cover too tight (max 0.054 Nm). If you have connectivity problems then please loosen the screws and tighten again the screws equally.

Do not clean NQPACK, YQPACK, and YQSOCKET with steam. Cleaning material will contaminate inside of connector.

FMEMCU-UG-960014-10

- 10 -

© Fujitsu Microelectronics Europe GmbH

Page 10
Image 10
Fujitsu MB96300 manual Installation, Connection/Power-On, Do not use any other probe cable than MB2198-507-E only