4.5ATA Commands

Table 4.18 lists supported ATA commands.

This section represents ODD registers as shown below.

Cylinders High/Low registers: CY

Sector register: SC

Device/Head register: DH

Sector Number register: SN

Features register: FR

Table 4.18 Command codes and parameters

Protocol

Command name

Command

 

Parameters used

 

Section

 

 

 

 

 

 

 

 

 

 

 

code

FR

SC

SN

CY

DH

 

 

 

 

 

 

 

 

 

 

PI

IDENTIFY PACKET DEVICE

A1h

 

 

 

 

D

4.5.1

 

 

 

 

 

 

 

 

 

-

PACKET

A0h

y

 

y

y

D

4.5.2

 

 

 

 

 

 

 

 

 

ND

DEVICE RESET

08h

 

 

 

 

D

4.5.3

 

 

 

 

 

 

 

 

 

ND

CHECK POWER MODE

98h E5h

 

y

 

 

D

4.5.4

 

 

 

 

 

 

 

 

 

ND

EXECUTE DEVICE DIAGNOSTIC

90h

 

 

 

 

D*

4.5.5

 

 

 

 

 

 

 

 

 

ND

GET MEDIA STATU

DAh

 

 

 

 

D

4.5.6

 

 

 

 

 

 

 

 

 

ND

IDLE IMMEDIATE

98h E5h

 

 

 

 

D

4.5.7

 

 

 

 

 

 

 

 

 

ND

NOP

00h

 

 

 

 

y

4.5.8

 

 

 

 

 

 

 

 

 

ND

SERVICE (Not supported)

A2h

 

 

 

 

D

4.5.9

 

 

 

 

 

 

 

 

 

ND

SET FEATURES

EFh

y

y

 

 

D

4.5.10

 

 

 

 

 

 

 

 

 

ND

SLEEP

99h E6h

 

 

 

 

D

4.5.11

 

 

 

 

 

 

 

 

 

ND

STANDBY IMMEDIATE

94h E0h

 

 

 

 

D

4.5.12

 

 

 

 

 

 

 

 

 

--

RESERVED: Other codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C156-E142-02EN