Fujitsu MCE3064AP, MCF3064AP, MCE3130AP manual 99 ASC/ASCQ list 2/2

Models: MCE3130AP MCE3064AP MCF3064AP

1 175
Download 175 pages 7 Kb
Page 133
Image 133

 

 

 

Table 4.99 ASC/ASCQ list (2/2)

 

 

 

 

Sense

ASC

ASCQ

Error description

Key

 

 

 

 

 

 

 

1

1C

00

DEFECT LIST NOT FOUND

 

 

 

 

5

20

00

INVALID COMMAND OPERATION CODE

 

 

 

 

5

21

00

LOGICAL BLOCK ADDRESS OUT RANGE

 

 

 

 

5

24

00

INVALID FIELD IN COMMAND PACKET

 

 

 

 

5

25

00

LOGICAL UNIT NOT SUPPORTED

 

 

 

 

5

26

00

INVALID FIELD IN PARAMETER LIST

 

 

 

 

7

27

00

WRITE PROTECTED

 

 

 

 

6

28

00

NOT READY TO READY TRANSITION, MEDIUM MAY HAVE

 

 

 

CHANGED

 

 

 

 

6

29

00

POWER ON, RESET, DEVICE RESET OCCURRED

 

 

 

 

3

30

00

INCOMPATIBLE MEDIUM INSTALLED

 

 

 

 

3

30

01

CANNOT READ MEDIUM/UNKNOWN FORMAT

 

 

 

 

3

31

00

MEDIUM FORMAT CORRUPTED

 

 

 

 

3

31

01

FORMAT COMMAND FAILED

 

 

 

 

3

32

00

NO DEFECT SPARE LOCATION AVAILABLE

 

 

 

 

3

32

01

DEFECT LIST UPDATE FAILURE

 

 

 

 

1

37

00

ROUNDED PARAMETER

 

 

 

 

2

3A

00

MEDIUM NOT PRESENT

 

 

 

 

4

40

NN

DIAGNOSTIC FAILURE ON COMPONENT NN

 

 

 

 

4

44

00

INTERNAL TARGET FAILURE

 

 

 

 

4

4A

00

COMMAND PHASE ERROR

 

 

 

 

4

4B

00

DATA PHASE ERROR

 

 

 

 

B

4E

00

OVERLAPPED COMMAND ATTEMPTED

 

 

 

 

2

53

00

MEDIA LOAD OR EJECT FAILED

 

 

 

 

5

53

02

MEDIUM REMOVAL PREVENTED

 

 

 

 

2/4

83

00

THERMAL ERROR

 

 

 

 

C156-E142-02EN

4 - 65

Page 133
Image 133
Fujitsu MCE3064AP, MCF3064AP, MCE3130AP manual 99 ASC/ASCQ list 2/2