Fujitsu MHW2120BS, MHW2100BS, MHW2080BS, MHW2040BS, MHW2060BS Check Power Mode X’98’ or X’E5’, ’Ff’

Models: MHW2040BS MHW2100BS MHW2060BS MHW2120BS MHW2080BS

1 296
Download 296 pages 17.62 Kb
Page 127
Image 127

5.3 Host Commands

(14) CHECK POWER MODE (X’98’ or X’E5’)

The host checks the power mode of the device with this command.

The host system can confirm the power save mode of the device by the contents of the Sector Count field after executing this command.

The device sets the following field value. After that, the device reports the status to the host system.

 

Power save mode

Sector Count field

 

 

• During moving to Standby mode

X’00’

Standby mode

 

 

 

 

Idle mode

X’FF’

 

 

 

Active mode

X’FF’

 

 

 

Error reporting conditions

(1)A SATA communication error occurred (ST = 51h, ER = 14h).

At command issuance (Shadow Block Registers setting contents)

CM

 

 

 

X’98’ or X’E5’

 

 

 

 

 

 

 

 

DH

x

x

x

x

 

xx

 

 

 

 

 

 

 

CH

 

 

 

xx

 

CL

 

 

 

xx

 

SN

 

 

 

xx

 

SC

 

 

 

xx

 

FR

 

 

 

xx

 

 

 

 

 

 

 

 

At command completion (Shadow Block Registers contents to be read)

ST

 

 

 

Status information

 

 

 

 

 

 

 

 

 

DH

x

x

x

 

x

 

xx

 

 

 

 

 

 

 

 

CH

 

 

 

 

xx

 

CL

 

 

 

 

xx

 

SN

 

 

 

 

xx

 

SC

 

 

 

 

X’00’ or X’FF’

 

ER

 

 

 

Error information

 

 

 

 

 

 

 

 

 

C141-E249

5-53

Page 127
Image 127
Fujitsu MHW2120BS, MHW2100BS, MHW2080BS, MHW2040BS, MHW2060BS manual Check Power Mode X’98’ or X’E5’, ’Ff’