5.3 Host Commands

SCT READ DATA (SN = E1h, FR = D5)

This command reads the data specified with SCT SET COMMAND and number of sectors specified Sector Count field

28-bit command

At command issuance (Shadow Block Registers setting)

CM

1

0

1

1

 

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

DH

x

x

x

DV

 

 

 

Xx

 

 

 

 

 

 

 

 

 

 

 

CH

 

 

 

Key (C2h)

 

 

 

 

CL

 

 

 

Key (4Fh)

 

 

 

 

SN

 

 

 

 

E1h

 

 

 

 

SC

 

 

 

 

xx

 

 

 

 

FR

 

 

 

 

D5h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (Shadow Block Registers contents to be read)

ST

 

 

Status information

 

 

 

 

 

 

 

 

DH

x

x

x

DV

 

xx

 

 

 

 

 

 

 

CH

 

 

 

xx

 

CL

 

 

 

xx

 

SN

 

 

 

xx

 

SC

 

 

 

xx

 

ER

 

 

Error information

 

 

 

 

 

 

 

 

SCT READ DATA Command issue procedure.

1.Issue the SCT set command of action code 0005h.

2.Issue the SCT READ DATA command and receive the HDA temperature data from the device.

C141-E249

5-83

Page 157
Image 157