Interface
Table 5.27 Action code
Code | Function | Data transfer | |
|
|
| |
0000h | Reserved | - | |
|
|
| |
0001h | Not supported | - | |
|
|
| |
0002h | WRITE SAME | Write | |
See Table 5.28. | |||
|
| ||
|
|
| |
0003h | ERROR RECOVERY CONTROL | - | |
See Table 5.29. | |||
|
| ||
|
|
| |
0004h | FEATURE CONTROL | - | |
See Table 5.30. | |||
|
| ||
|
|
| |
0005h | SCT DATA TABLE | Read | |
See Table 5.31. | |||
|
| ||
|
|
| |
0006h |
|
| |
to | Reserved | - | |
BFFFh |
|
| |
|
|
| |
C000h |
|
| |
to | Vender Specific | - | |
FFFFh |
|
| |
|
|
|
Table 5.28 WRITE SAME (1/2)
Byte | Name | Value | Description | |
|
|
|
| |
000h | Action Code | 0002h | WRITE SAME | |
001h | ||||
|
|
| ||
|
|
|
| |
|
|
| Repeat Write Pattern | |
|
| 0001h | It initializes it by data pattern of 32bit specified with | |
|
|
| byte | |
|
|
|
| |
002h | Function Code | 0002h | Repeat Write data block | |
003h | It initializes it by data pattern of 1sct transfer by the | |||
| ||||
|
|
| SCT Write data. | |
|
| 0101h | Repeat Write Pattern Foreground | |
|
|
|
| |
|
| 0102h | Repeat Write data block Foreground | |
|
|
|
| |
004h |
|
|
| |
to | LBA | (8 byte) | Start LBA | |
00Bh |
|
|
| |
|
|
|
|