Interface
•Error reporting conditions
(1)The command has been issued more than twice (ST = 51h, ER = 10h).
(2)The READ NATIVE MAX ADDRESS command has not been issued prior to the SET MAX ADDRESS command. (ST = 51h, ER = 04h).
(3)The SET MAX ADDRESS (EXT) command has been issued (ST = 51h, ER = 04h).
(4)A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block Registers setting contents)
CM | 1 | 1 | 1 | 1 | 1 | 0 | 0 | 1 |
|
|
|
|
|
|
| ||
DH | x | L | x | x | HD No./LBA |
| ||
|
|
|
|
|
|
|
|
|
CH |
| CYL No. [MSB] / LBA |
|
|
| |||
CL |
| CYL No. [LSB] | / LBA |
|
|
| ||
SN |
| SCT No. |
| / LBA[LSB] |
|
| ||
|
|
|
|
|
|
|
|
|
SC |
|
|
| xx |
|
|
| VV |
|
|
|
|
|
|
|
| |
FR |
|
|
| xx |
|
|
| |
|
|
|
|
|
|
|
|
|
At command completion (Shadow Block Registers contents to be read)
ST |
|
|
|
| Status information | |
|
|
|
|
|
|
|
DH | x | x | x |
| x | xx |
|
|
|
|
|
| |
CH |
| CYL No. [MSB] / LBA | ||||
CL |
| CYL No. [LSB] | / LBA | |||
SN |
| SCT No. | / LBA[LSB] | |||
SC |
|
|
|
| xx | |
ER |
|
|
| Error information | ||
|
|
|
|
|
|
|
•SET MAX SET PASSWORD (Features Field = 01h)