5.3 Host Commands

(10) STANDBY IMMEDIATE (X’94’ or X’E0’)

Upon receipt of this command, the device enters the standby mode. The device then reports the status to the host system. This command does not support the APS timer function.

Error reporting conditions

(1)A SATA communication error occurred (ST = 51h, ER = 14h).

At command issuance (Shadow Block Registers setting contents)

CM

 

 

 

X’94’ or X’E0’

 

 

 

 

 

 

 

 

DH

x

x

x

x

 

Xx

 

 

 

 

 

 

 

CH

 

 

 

xx

 

CL

 

 

 

xx

 

SN

 

 

 

xx

 

SC

 

 

 

xx

 

FR

 

 

 

Xx

 

 

 

 

 

 

 

 

At command completion (Shadow Block Registers contents to be read)

ST

 

 

 

Status information

 

 

 

 

 

 

 

 

 

DH

x

x

x

 

x

 

Xx

 

 

 

 

 

 

 

 

CH

 

 

 

 

xx

 

CL

 

 

 

 

xx

 

SN

 

 

 

 

xx

 

SC

 

 

 

 

xx

 

ER

 

 

 

Error information

 

 

 

 

 

 

 

 

 

C141-E249

5-47

Page 121
Image 121
Fujitsu MHW2080BS, MHW2100BS, MHW2120BS, MHW2040BS, MHW2060BS manual Standby Immediate X’94’ or X’E0’