Fujitsu MHY2120BH, MHY2160BH, MHY2200BH manual Shadow block registers, Error Field, Unc, Sfrr, Amnf

Models: MHY2120BH MHY2200BH MHY2100BH MHY2160BH MHY2040BH MHY2060BH MHY2080BH MHY2250BH

1 322
Download 322 pages 60.82 Kb
Page 100
Image 100

Interface

5.2.4 Shadow block registers

(1)Error Field

The Error Field indicates the status of the command executed by the device.

The fields are valid when the ERR bit of the Status field is 1.

This register contains a diagnostic code after power is turned on, the COMRESET or the EXECUTIVE DEVICE DIAGNOSTIC command is executed.

[Status at the completion of command execution other than diagnostic command]

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

 

 

 

 

 

 

 

 

X

UNC

X

IDNF/ SFRW

SFRR

ABRT

TK0NF

AMNF

 

 

 

 

 

 

 

 

X: Unused

 

 

 

 

 

 

-Bit 7: Unused

-Bit 6: Uncorrectable Data Error (UNC). This bit indicates that an uncorrectable data error has been encountered.

-Bit 5: Unused

-Bit 4: ID Not Found (IDNF). This bit indicates an error except for bad sector, uncorrectable error and SB not found.

Or, SATA Frame Error Write (SFRW) This bit indicates that a SATA communication error has been encountered during the write process. In this case, bit4 and bit2 are set both.

-Bit 3: SATA Frame Error Read (SF RR). This bit indicates that a SATA communication error has been encountered during the read process. In this case, bit3 and bit2 are set both.

-Bit 2: Aborted Command (ABRT). This bit indicates that the requested command was aborted due to a device status error (e.g. Not Ready, Write Fault) or the command code was invalid.

-Bit 1: Track 0 Not Found (TK0NF). This bit indicates that track 0 was not found during RECALIBRATE command execution.

-Bit 0: Address Mark Not Found (AMNF). This bit indicates that the SB Not Found error occurred.

[Diagnostic code]

-X '00': Format Unit is not completed.

-X '01': No Error Detected.

-X '02': HDC Diagnostic Error

-X '03': Data Buffer Diagnostic Error

-X '04': Memory Diagnostic Error

-X '05': Reading the system area is abnormal.

-X '06': Calibration is abnormal.

5-22

C141-E262