Fujitsu MHY2060BH, MHY2160BH, MHY2200BH manual Digital PLL circuit, FIR circuit, D converter circuit

Models: MHY2120BH MHY2200BH MHY2100BH MHY2160BH MHY2040BH MHY2060BH MHY2080BH MHY2250BH

1 322
Download 322 pages 60.82 Kb
Page 70
Image 70

Theory of Device Operation

(3) FIR circuit

This circuit is 10-tap sampled analog transversal filter circuit that equalizes the head read signal to the Modified Extended Partial Response (MEEPR) waveform.

(4) A/D converter circuit

This circuit changes Sampled Read Data Pulse from the FIR circuit into Digital Read Data.

(5) Viterbi detection circuit

The sample hold waveform output from the flash digitizer circuit is sent to the Viterbi detection circuit. The Viterbi detection circuit demodulates data according to the survivor path sequence.

4.6.4 Digital PLL circuit

The drive uses constant density recording to increase total capacity. This is different from the conventional method of recording data with a fixed data transfer rate at all data area. In the constant density recording method, data area is divided into zones by radius and the data transfer rate is set so that the recording density of the inner cylinder of each zone is nearly constant. The drive divides data area into 30 zones to set the data transfer rate.

The MPU set the data transfer rate setup data (SD/SC) to the RDC block that includes the Digital PLL circuit to change the data transfer rate.

4-12

C141-E262

Page 70
Image 70
Fujitsu MHY2060BH, MHY2160BH, MHY2200BH Digital PLL circuit, FIR circuit, D converter circuit, Viterbi detection circuit