Fujitsu MHY2160BH, MHY2200BH, MHY2250BH, MHY2100BH, MHY2120BH manual Initialize Device Parameters X

Models: MHY2120BH MHY2200BH MHY2100BH MHY2160BH MHY2040BH MHY2060BH MHY2080BH MHY2250BH

1 322
Download 322 pages 60.82 Kb
Page 120
Image 120

Interface

(8)INITIALIZE DEVICE PARAMETERS (X '91')

The host system can set the number of sectors per track and the maximum head number (maximum head number is "number of heads minus 1") per cylinder with this command. Upon receipt of this command, the device sets the parameters. Then the device reports the status to the host system.

When the SC field is specified to X '00', an ABORTED COMMAND error is posted. Other than X '00' is specified, this command terminates normally.

The parameters set by this command are retained even after soft reset and COMRESET issuance or power save operation regardless of the setting of disabling the reverting to default setting.

The operation is always performed in CHS mode, with the command ignoring any setting of LBA mode.

Error reporting conditions

(1)"00h" is specified in the SC field (ST = 51h, ER = 04h).

(2)A SATA communication error occurred (ST = 51h, ER = 14h).

At command issuance (Shadow Block Registers setting contents)

CM

1

0

0

1

0

0

0

1

 

 

 

 

 

 

 

 

DH

x

x

x

x

 

Max. head No.

 

 

 

 

 

 

 

 

 

 

CH

 

 

 

 

xx

 

 

 

CL

 

 

 

 

xx

 

 

 

SN

 

 

 

 

xx

 

 

 

SC

 

 

Number of sectors/track

 

 

FR

 

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (Shadow Block Registers contents to be read)

ST

 

 

 

Status information

 

 

 

 

 

 

 

DH

x

x

x

 

x

Max. head No.

 

 

 

 

 

 

 

CH

 

 

 

 

 

xx

CL

 

 

 

 

 

xx

SN

 

 

 

 

 

xx

SC

 

 

Number of sectors/track

ER

 

 

 

Error information

 

 

 

 

 

 

 

5-42

C141-E262

Page 120
Image 120
Fujitsu MHY2160BH, MHY2200BH, MHY2250BH, MHY2100BH, MHY2120BH, MHY2080BH, MHY2060BH, MHY2040BH Initialize Device Parameters X