1.3 Power Requirements

(5) Current Requirements and Power Dissipation

Table 1.3 lists the current and power dissipation (typical).

Table 1.3 Current and power dissipation

 

Typical RMS Current

Typical Power (*3)

 

 

 

Spin up (*1)

1.0 A

5.0 W

 

 

 

Idle (*6)

120 mA

0.60 W

 

 

 

R/W (on track) (*2)

380 mA

1.9 W

 

 

 

Seek (*5)

420 mA

2.1 W

 

 

 

Standby (*6)

26 mA

0.13 W

 

 

 

Sleep (*6)

26 mA

0.13 W

 

 

 

 

 

e rank (0.0024 W/GB): MHY2250BH

 

 

e rank (0.0030 W/GB): MHY2200BH

 

 

e rank (0.0038 W/GB): MHY2160BH

Energy

d rank (0.0050 W/GB): MHY2120BH

Efficiency (*4)

d rank (0.0060 W/GB): MHY2100BH

 

 

 

d rank (0.0075 W/GB): MHY2080BH

 

 

d rank (0.0100 W/GB): MHY2060BH

 

 

d rank (0.0150 W/GB): MHY2040BH

 

 

 

*1 Maximum current and power at starting spindle motor.

*2 Current and power level when the operation (command) that accompanies a

 

transfer of 63 sectors is executed 3 times in 100 ms

*3 Power requirements reflect typical values for +5 V power.

*4 Energy efficiency based on the Law concerning the Rational Use of Energy

 

indicates the value obtained by dividing power consumption by the storage

 

capacity. (Japan only)

 

*5 The seek average current is specified based on three operations per 100

 

msec.

 

*6 IPM mode: Slumber mode.

 

C141-E262

1-9

Page 33
Image 33