Disk Drives PRODUCT/MAINTENANCE Manual
Handling of This Manual
For Safe Operation
Revision History
This page is intentionally left blank
Acronyms and Abbreviations
Conventions for Alert Messages
Operating Environment
Overview of Manual
Preface
Liability Exception
Conventions
Hot Plug
Static, Damage
Important Alert Items
Important Alert Messages
Damage or Device damage
Device damage
Data corruption
Manual Organization
Disk Drives PRODUCT/MAINTENANCE Manual
This page is intentionally left blank
Contents
Theory of Device Operation
Installation Conditions
Interface
Contents
100
Operations
Maintenance and Diagnosis
Glossary GL-1 Acronyms and Abbreviations AB-1 Index IN-1
Figures
Illustrations
Response to power-on when the device is powered on
Tables
Surface temperature measurement points and standard values
105
This page is intentionally left blank
Device Overview
Adaptability
Features
Functions and performance
Error correction and retry by ECC
Wide temperature range
Low noise and vibration
High resistance against shock
Specifications summary
Device Specifications
Specifications 1/2
Self-diagnosis
Model and product number
Specifications 2/2
Examples of model names and product numbers
Input Voltage
Power Requirements
Ripple
Slope of an input voltage at rise
Permissible level − 0.2
Current and power dissipation
Current Requirements and Power Dissipation
Environmental specifications
Environmental Specifications
Current fluctuation Typ. at +5 V when power is turned on
Shock and vibration specification
Acoustic noise specification
Acoustic Noise
Shock and Vibration
Data assurance in the event of power failure
Service life
Reliability
Mean time between failures Mtbf
Unrecoverable read error
Error Rate
Positioning error
Media Defects
Recommended power-off sequence
Advanced Power Management APM
Advanced Power Management
Device-initiated interface power management Dipm
Interface Power Management IPM
Host-initiated interface power management Hipm
Interface power management
This page is intentionally left blank
Device Configuration
Disk
Device Configuration
Head
Spindle motor
Drive connection
System Configuration
Sata interface
This page is intentionally left blank
Installation Conditions
Dimensions
Dimensions
Integration Guidance C141-E144
Mounting
Orientation
Frame
PCA
Limitation of mounting
Location of breather
Ambient temperature
Handling cautions
Service area
Hios
ESD
Sumitomo 3M
Connections with Host System
Device connector
Connector specifications for host system
Signal segment and power supply segment
Sata interface cable connection
This page is intentionally left blank
Theory of Device Operation
Subassemblies
Outline
Disk
Spindle
Air filter
Circuit Configuration
Servo circuit
Spindle motor driver circuit
Power supply configuration
PCA
Power-on Sequence
Power-onStart
Self-calibration
Self-calibration contents
Execution timing of self-calibration
Command processing during self-calibration
Read/write preamplifier PreAMP
Read/write Circuit
Write circuit
Write precompensation
Programmable filter circuit
Read circuit
AGC circuit
FIR circuit
Digital PLL circuit
D converter circuit
Viterbi detection circuit
Servo control circuit
Servo Control
Microprocessor unit MPU
Power amplifier
Servo burst capture circuit
A converter DAC
Data-surface servo format
Physical sector servo configuration on disk surface
Servo frame format
Operation to move the head to the reference cylinder
Actuator motor control
Seek operation
Track following operation
Acceleration mode
Start mode
Stable rotation mode
Spindle motor control
This page is intentionally left blank
Interface
Physical Interface
Interface signals
5VDC/GND
Comreset / Cominit
Comwake
Out of band signaling
Signal interface regulation
Primitives descriptions
Electrical specifications
Connector pinouts
Connector pinouts
Driving Activity LED
5 P11 function
Staggered Spin-up
Example of the circuit for driving Activity LED
Requirements for P11 as an output pin
Hot Plug
Logical Interface
Conceptual diagram of communication layers
Physical layer
Communication layers
Link layer
Transport layer
Shadow Block Register
Outline of the Shadow Block Register
FIS types
Outline of the frame information structure FIS
Register Host to Device FIS layout
Register Host to Device
DMA Active Device to Host
Register Device to Host
TAG
DMA Setup Device to Host or Host to Device Bidirectional
Bist combinations
Bist Active Bidirectional
Data Host to Device or Device to Host Bidirectional
PIO Setup Device to Host
Interface
11 Set Device Bits FIS
Set Device Bits Device to Host
Shadow block registers
Error Field
UNC
Sfrr
Sector Count Field exp
Features Field exp
Sector Number Field exp
Cylinder Low Field exp
Device/Head Field
Cylinder High Field exp
HS3
HS2 HS1 HS0
DSC DRQ ERR
Status field
BSY
Bit 2 Software Reset Srst
Command Field
Device Control Field
EStatus Field
Command code and parameters 1/3
Host Commands
Command code and parameters
Command code and parameters 2/3
Command code and parameters 3/3
Command descriptions
Recalibrate X 10 to X 1F
Error reporting conditions
Read Sectors X 20 or X
LBA
LBA LSB
Write Sectors X 30 or X
00 *1 Error information
Write Verify X 3C
Host Commands
Read Verify Sectors X 40 or X
Host Commands
Seek X 70 to X 7F
Diagnostic code
Execute Device Diagnostic X
Initialize Device Parameters X
Download Microcode X
Operation of Download Microcode
Microcode
Standby Immediate X 94 or X E0
Host Commands
Unload Feature Unload Immediate Command
Standby X 96 or X E2
Idle X 97 or X E3
Host Commands
Check Power Mode X 98 or X E5
Sleep X 99 or X E6
Comreset
Smart X B0
Features Field values subcommands and functions 1/3
Smart Enable Operations
Features Field values subcommands and functions 2/3
Smart Read LOG
Smart Write LOG
Smart Disable Operations
Features Field values subcommands and functions 3/3
Smart ENABLE/DISABLE Auto OFF-LINE
Smart Return Status
Key C2h Key 4Fh
1FF
11 Format of guarantee failure threshold value data
10 Format of device attribute value data
Attribute ID
Data format version number
Current attribute value
Status Flag
Attribute value for the worst case so far
Raw attribute value
13 Self-test execution status
12 Off-line data collection status
Self-test execution status
14 Off-line data collection capability
Off-line data collection capability
Failure prediction capability flag
15 Failure prediction capability flag
16 Drive error logging capability
Error logging capability
Guarantee failure threshold
Checksum
18 Data format of Smart Summary Error Log 1/2
Smart error logging
Command data structure
18 Data format of Smart Summary Error Log 2/2
Error data structure
Total number of drive errors
Smart Self-Test
19 Data format of Smart Comprehensive Error Log
Status
1FC
20 Smart self-test log data format
Self-test number
Self-test index
Current LBA under test
21 Selective self-test log data structure
Test Span
22 Selective self-test feature flags
Feature Flags
Smart Command Transport SCT
Current Span under test
SCT Command SET
23 SCT command and the function
SCT Status Request
SCT Read Data
SCT Status Request SN = E0h, FR = D5h
SET MAX EXT, DCO
24 Format of SCT Status Response 1/2
24 Format of SCT Status Response 2/2
25 SCT Status code
SCT Command SET SN = E0h, FR = D6
27 Write Same 1/2
26 Action code
27 Write Same 2/2
28 Error Recovery Control
29 Feature Control Command
30 SCT Data Table
31 had Temperature
SCT Read Data SN = E1h, FR = D5h
SCT Write Data SN = E1h, FR = D6h
Device Configuration Restore
Device Configuration X B1
Device Configuration Freeze
Device Configuration Identify
Device Configuration Freeze Lock Features Field = C1h
Device Configuration Restore Features Field = C0h
Device Configuration SET Features Field = C3h
Device Configuration Identify Features Field = C2h
32 Device Configuration Identify data structure 1/2
32 Device Configuration Identify data structure 2/2
Read Multiple X C4
12 Execution example of Read Multiple command
LBA LSB
Write Multiple X C5
At command issuance Shadow Block Registers setting contents
SET Multiple Mode X C6
Host Commands
Read DMA X C8 or X C9
LBA
Write DMA X CA or X CB
Host Commands
Read Buffer X E4
Flush Cache X E7
Write Buffer X E8
Identify Device X EC
Identify Device DMA X EE
33 Information to be read by Identify Device command 1/3
33 Information to be read by Identify Device command 2/3
33 Information to be read by Identify Device command 3/3
MHY2100BH MHY2080BH MHY2060BH MHY2040BH
MHY2250BH MHY2200BH MHY2160BH MHY2120BH
Fffffff
Command without interrupt supports 1, 2, 4, 8 and 16 sectors
Word 63 Multiword DMA transfer mode
C141-E262 111
Interface
C141-E262 113
Bits 13-0 Same definition as Word
Undefined
= Read and Write DMA EXT GPL optional commands are
Host Commands
Download
34 Features field values and settable modes 1/2
SET Features X EF
34 Features field values and settable modes 2/2
Error reporting conditions
Data Transfer Mode
Advanced Power Management APM
Serial ATA Functions
Automatic Acoustic Management AAM
Write-Read-Verify feature optional
35 Contents of Security SET Password data
Error reporting conditions
Security Unlock X F2
When the master password is selected
When the user password is selected
Host Commands
Security Erase Prepare X F3
Security Erase Unit X F4
Security Freeze Lock X F5
Error reporting conditions
37 Contents of security password
Error reporting conditions
Lbalsb
Read Native MAX Address X F8
SET MAX Address
SET MAX X F9
SET MAX SET Password Features Field = 01h
Password information
SET MAX Lock Features Field = 02h
SET MAX Unlock Features Field = 03h
SET MAX Freeze Lock Features Field = 04h
Read Sector S EXT X Description
Read DMA EXT X Description
Read Native MAX Address EXT X
Read Multiple EXT X
Read LOG EXT X 2F
Sector offset
39 Tag field information
38 Data format of Read Log Ext log page 10h
41 Counter Identifier information
40 Data format of Read Log Ext log page 11h
FR EXP
SCT Status Request SN = E0h
SC EXP
SCT Read Data SN = E1h, FR = D5
Write Sector S EXT X Description
Write DMA EXT X Description
SET MAX Address EXT X
SET MAX LBA
Write Multiple EXT X
Write DMA FUA EXT X 3D
Write LOG EXT X 3F
Error information 160 C141-E262
SCT Command SET SN = E0h
SCT Write Data SN = E1h
Read Verify Sector S EXT X
Write Uncorrectable EXT X
42 Operation mode
Read LOG DMA EXT X Description
Write LOG DMA EX X Description
Read FP DMA Queued X Description
Write FP DMA Queued X
Write Multiple FUA EXT X CE
Flush Cache EXT X EA
43 Command code and parameters 1/2
Error posting
Command Name
Sfrw Sfrr
DWF
43 Command code and parameters 2/2
Data
Command Protocol
Execute Device Diagnostic Initialize Device Parameters
Non-data command protocol
Host
PIO data-in command protocol
14 PIO data-in command protocol
PIO data-out command protocol
15 PIO data-out command protocol
Read DMA EXT Identfy Device DMA Read LOG DMA EXT
DMA data-in command protocol
Write DMA EXT FUA EXT Write LOG DMA EXT
DMA data-out command protocol
Read FP DMA Queued Write FP DMA Queued
Native Command Queuing protocol
18 Read FP DMA Queued command protocol
19 Write FP DMA Queued command protocol
20 Power-on sequence
Power-on and Comreset
21 Comreset sequence
This page is intentionally left blank
Operations
Response to power-on
Reset and Diagnosis
Reset and Diagnosis
Response to Comreset
Response to Comreset
Comreset preservation requirements
Software settings preservation
SET Address MAX EXT
Response to a software reset
Response to a software reset
Power save mode
Power Save
Active mode
Active idle mode
Sleep mode
Standby mode
Power commands
Partial mode
Power Save Controlled by Interface Power Management IPM
Power save mode of the interface
Slumber mode
Data buffer structure
Read-ahead Cache
Example of 8 MB buffer
Read Sector S EXT
Data that is a target of caching
Commands that are targets of caching
Caching operation
Invalidating caching-target data
Miss-hit
Using the read segment buffer
Sequential hit
Full hit
Partial hit
Write Cache
Command that are targets of caching
Cache operation
Invalidation of cached data
Comreset and software reset response
Status report in the event of an error
Cashing function when power supply is turned on
Enabling and disabling
This page is intentionally left blank
Maintenance and Diagnosis
Rules for maintenance
Maintenance
Maintenance requirements
Data corruption
Maintenance levels
Disk drive revision number label
Disk drive revision number
Display of disk drive revision number
Test
Self-diagnostics
Tools and test equipment
Test flowchart
Disposition for Error Field contents
Status Field contents
Operation test
Diagnostic test
Operation Confirmation
Troubleshooting disk drive replaced in field
Troubleshooting Procedure
Troubleshooting procedure
VDC
System level and field troubleshooting
Troubleshooting at factory
Spare Disk Drive
Disk Drive Removal Procedure
This page is intentionally left blank
Glossary
Rotational delay
Power save mode
Master Device
PIO Programmed input-output
Status
Serial-ATA
Slave Device
This page is intentionally left blank
Acronyms and Abbreviations
This page is intentionally left blank
Caching
Index
Index
Example of model name and product
Mode
Read Native MAX Address
Read/write circuit block diagram
Shadow block register, outline
Japan
Comment Form
This page is intentionally left blank
C141-E262-01EN
Page