Interface

Table 5.27 WRITE SAME (2/2)

Byte(hex)

Name

Value

Description

 

 

 

 

0C to13

Count

(8 byte)

Number of Sectors

 

 

 

 

14 to17

Pattern

(4 byte)

If the Function Code is 0001h, this field contains a

32-bit pattern that is written on the media.

 

 

 

 

 

 

 

18 to 1FF

(Reserved)

-

Reserved

 

 

 

 

* It is invalid excluding the description value.

Table 5.28 ERROR RECOVERY CONTROL

Byte(hex)

Name

Value

Description

 

 

 

 

00, 01

Action Code

0003h

ERROR RECOVERY CONTROL

 

 

 

 

 

 

 

Set New Value

 

 

0001h

The retry processing when making an error in the

02, 03

Function

 

specified timer

Code

 

Return Current Value

 

 

 

 

 

 

 

0002h

The timer value of the error recovery being set now

 

 

 

is displayed in SN /SC field.

 

 

 

 

04, 05

Selection

0001h

Read Timer

Code

0002h

Write Timer

 

 

 

 

 

 

 

 

 

 

Set to Timer Value (x 100 ms)

 

 

 

Minimum value is 10 sec.

06, 07

Value

(2 byte)

(ex.) 0000h: Disable timeout

 

 

 

0063h: Invalid

 

 

 

0064h: 10000 ms (10 s)

 

 

 

 

08 to 1FF

(Reserved)

-

Reserved

 

 

 

 

* It is invalid excluding the description value.