Fujitsu TX150 S3 manual Conversion standard PS to hot- plug PS, V Caution

Models: TX150 S3

1 95
Download 95 pages 1.83 Kb
Page 49
Image 49
10Conversion standard PS to hot- plug PS

10Conversion standard PS to hot- plug PS

VCAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .

The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of up to two power supply modules. The upgrade kit contains only one power supply module (for power supply redundancy the second power supply module must be additionally ordered).

The upgrade kit for the hot-plug power supply consists of the following parts:

PS cage with Power backplane (incl. power cables)

locking rail

one power supply unit

dummy cover (if only one power supply module is installed, you have to install the dummy cover in the second bay)

several screws

anti-tilt bracket

VCAUTION!

After installing the hot-plug power supply the SDR (sensor data record) data base must be updated. For this sequence you need a BIOS flash diskette. This diskette contains the newest BIOS version, the BMC firmware and the SDR data.

ÊWrite a BIOS flash diskette by down loading the required data from the software pool under http://service.abg.fsc.net/support/softwareAssist.asp.

ÊOpen the server as described in the chapter “Preparation” on page 13 et seqq. .

ÊDisconnect all power cables from the system board and the drives (see the cabling plans in the Appendix).

U41604-Z156-1-76

Options Guide

41

Page 49
Image 49
Fujitsu TX150 S3 manual Conversion standard PS to hot- plug PS, V Caution