Diagnostics Mode

OPERATING INSTRUCTIONS continued...

Diagnostics Mode

To enter Diagnostics Mode, press and hold the Program (lower right blank) button for three, (3), seconds. When prompted, enter the code: 3-4-2- 4 using the buttons 1 – 0. Press “ENTER” (lower right blank).

After entering the code and pressing “ENTER,” the Moisture Plus Part Number will be displayed briefly and then the display will change to Diagnostics Test – Buttonpad Test. Use the “YES” (upper right blank) and “NO” (Preheat Bread 425) buttons to scroll through the available diagnostic tests. Press “ENTER” to begin the desired test.

Buttonpad Test

1.The display will show “Press the On/Off Button”. Upon pressing the On/Off button, the LED for the ON/OFF button will light briefly and then go out to show that the button works.

2.The display will then prompt the user to press the “TEMP” button (upper right blank). After the user presses the “TEMP” (upper right blank) button, the corresponding LED will light to show the button works. The control will then continue to prompt the user to press the remaining control buttons. If the LED of the button pressed does not

light, a buttonpad problem exists. After completing the Buttonpad Test, you will return to Diagnostics Mode. (Press “CANCEL” at any time during the test to return to Diagnostics Mode.)

Door Switch Test

1.After selecting Door Switch Test and pressing the “ENTER” (lower right blank) button, the display will show the position of each of the two switches. Open and close the door slowly to verify the operation of the door switches.

Proper Door Switch Activation:

Starting with the door closed, the switches should read:

Slowly begin to open the door. Door switch 1 should be the first to change states:

Next, door switch 2 should change state to:

If the switches do not operate as stated above, there is a problem with the door switches.

Press “CANCEL” to exit the Door Switch Test and return to Diagnostic Mode.