Magnum 6K32 Managed Switch

Installation and User Guide (02/05)

With each bracket type, there are three different mounting options is shown in Fig. 3.3.2. The case of the Magnum 6K32 has mounting holes prepared for each of the mounting arrangements. Users may choose the mounting arrangement most suitable for their installation.

D

D C

 

C

B

 

B

A

D

D C

C

B

B

A

 

A

D D C C BB AA

Standard Flush

Mount Bracket

Mid-Range Mount or

Rear Mount

Fig 3.3.2 Reverse Magnum 6K32 units, rack- mounted in a frame

3.4Powering the Magnum 6K32 Managed Switch

The Magnum 6K32 Switches incorporate an internal universal power supply

and have a recessed male IEC connector for the AC power cord at the left-rear. A manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power cord is supplied with each unit shipped within the United States and Canada.

The auto-ranging power supply supports installation environments where the AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz. The 32-port units will consume over 30 watts of power typically. When connecting the Ethernet cabling, there is no need to power down the unit. Individual segments can be connected or disconnected without concern for AC power-related problems or damage to the unit.

Power supply options are available to suit the 6K32 Switches to special high- availability communications and/or heavy industrial-grade applications, including:

*-48VDC, 24VDC and 125VDC with single DC input,

*-48VDC, 24VDC and 125VDC with dual-source DC input,

See the Appendices of this manual for more details. Use an RFQ for other variations.

3.4.1Alarm Contacts for monitoring internal power, and Software Traps

The Alarm Contacts feature, optional on Magnum 6K32’s, provides two