Magnum 6K32 Managed Switch Installation and User Guide (02/05)
www GarrettCom com
..
Fiber connector types supported:
ST-type (twist-lock)
SC-type (snap-in)
MTRJ-type Small Form Factor (SFF)
LC-type Small Form Factor (SFF) GBIC modules
LEDs: Per Port
LK: Steady ON when media link is operational
ACT: ON with receiver port activity
FDX/HDX: ON = Full-Duplex Mode
OFF = Half-Duplex Mode
100/10: ON = 100Mbps speed
OFF = 10 Mbps
Operating Environment
Ambient Temperature: 25° to 130° F (-5° to 55°C)
Storage Temperature: -40°to 185°F (-40°to 85°C)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating option: Request quote
Packaging
Enclosure: Rugged High strength metal. Suitable for stand-alone
or rack-mounting
Dimensions: 1.70in. H x 17.0in. W x 9.0in. D
4.32cm H x 43.2cm W x 22.9cm D
Cooling method: Fan cooled, @ 3@ 7 cfm ea.
Management Console connector
DB-9 for RS-232 “ null-modem “ cable (sometimes called an X-modem cable)
Power Supply (Internal)
AC Power Connector: IEC-type, male recessed at rear of chassis,
with adjacent manual ON-OFF switch (optional if no Alarms Cont.)
Input Voltage: 100 to 240 VAC (auto-ranging)
Input Frequency: 47 to 63 Hz (auto-ranging)
Power Consumption: 45 watts max (with fiber module)
30 watts for a fully-loaded copper only model
DC Power Supply (Options)
-48VDC Power Input Voltage : -36 to -70 VDC
24VDC Power Input Voltage : 20 to 40VDC
125VDC Power and 100VDC Input Voltage : 88 to 150VDC
Std. Terminal Block : “ -, GND, + ”
Power Consumption: same as for AC models, see above
For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (for continuity of operation when either of the DC
input sources are interrupted)
, see Appendices B and C.