Magnum 6KQ Managed Field Switch Installation and User Guide

(04/07)

air circulation and cooling of the rear part of the case.

For best cooling of the 6KQ, attach the metal brackets to metal (rather than wood or plastic). Attaching to metal helps conduct heat away from the 6KQ through the metal brackets and into the metal support structure.

Since the 6KQ has special internal thermal techniques (patent pending) to move the heat generated by the electronic components inside into the case, the case may be quite warm to the touch during normal operation.

The unit is mounted using the brackets as shown in the illustration above. The spacing for the mounting screws into the supporting wall or panel is a rectangle 21.74 x 11.91 cm (8.56 x 4.69 inches) center-to-center.

3.4Powering the Magnum 6KQ Managed Field Switch

The DC internal power supply supports installation environments where the

DC voltage is from 18 to 150 volts depending on the model selected. The power

www . GarrettCom . com

27