Magnum 6KQ Managed Field Switch Installation and User Guide | (04/07) |
“+ve potential”. The more “+ve” voltage lead from 48V or
The connection procedure is straightforward. Simply connect the DC leads to the Switch’s power terminals, positive (+) and negative
C5.1 UL Requirements
The following must be adhered to in order to conform to UL requirements:
1.Minimum 18 AWG cable for connection to a Centralized DC power source.
2.Minimum 14 AWG cable for connection to earthing wiring.
3.Use only with Listed 10 A circuit breaker provided in building installation.
4.“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5.Fastening torque of the lugs on the terminal block: 9 inch pound max.
6.Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block.
C6.0 ORDERING INFORMATION
To order the optional
Example: Magnum
Similarly, order the “Dual
Example: Magnum 6KQ-24VDC or Magnum P6KQ-125VDC
Or Dual-Src125V-Switch
See the Configuration Guide on the GCI web site at http://www.garrettcom.com/techsupport/insertion_guides/6kqcg.pdf for additional information.
C7.0 OPERATION
Operation of the
www . GarrettCom . com
50