Control Panel

A

C

B

D

EG

FH

IK

JL M

Fig. 5-13. Control Panel.

A. Ready Indicator

The Ready Indicator informs the operator that the machine has reached the desired set temp of the Top Main Roller.

B. Temperature Display

The Temperature Display shows the Set Temperature of the laminator.

C. Speed Display

The Speed Display shows the set speed of the laminator.

Temp Section

D. MES (Measure)

Press MES to show the actual Top Main Roller Temperature.

E. Temp Arrow Up

To increase the Top Main Roller temperature, press and hold.

F. Temp Arrow Down

To decrease the Top Main Roller temperature, press and hold.

G. HOT

For the factory preset temperature of the Top Main Roller, press HOT.

H. COLD

For the factory preset temperature of the Top Main Roller, press COLD

Speed Section

I. Speed Arrow Up Symbol

To increase the Roller speed, press and hold.

J. Speed Arrow Down Symbol

To Decrease the Roller speed, press and hold.

K. RUN

Press and release RUN for continuous running.

L. STOP

Press STOP to stop the machine.

M. REV (Reverse)

Press and hold REV to reverse the direction of the rollers. Release REV to stop. When in the reverse mode, the machine will operate at 3 fpm, (0.9mpm)