ORCA-IV Image Transfer Laminator Operation Manual

Maintenance and Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

Problem

 

Possible Cause

 

 

Corrective Action

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

I pressed the motor forward

a.

Has a speed setting been set?

a.

Press the FWD or REV arrow and

 

button, but the rolls would

b. Are the doors closed and shafts

 

turn the speed control up.

 

 

locked in?

 

b.

Close the doors and lock in the

 

not turn!

 

 

 

c.

Are the e-stop buttons pressed?

 

unwind/rewind shafts.

 

 

 

 

 

 

Are the kick cables reset?

 

c.

Make sure all safety buttons are

 

 

d. Is there decimal on display?

 

 

released (out). Be sure all kick

 

 

e.

Check motor fuses on the back of

 

cables are reset and adjusted

 

 

 

machine.

 

 

properly. Press the machine reset

 

 

 

 

 

 

(above main switch). See

 

 

 

 

 

 

"Machine Reset Procedure" on

 

 

 

 

 

 

page 3-3. Verify that the kick

 

 

 

 

 

 

cable is truly resetting (listen,

 

 

 

 

 

 

look). Adjust the kick cable. See

 

 

 

 

 

 

“Adjusting the Kick Cable” on

 

 

 

 

 

 

page 3-3.

 

 

 

 

 

d.

Press the machine reset (above

 

 

 

 

 

 

main switch). See "Machine

 

 

 

 

 

 

Reset Procedure" on page 3-3.

 

 

 

 

 

e.

Remove fuses and replace, if nec-

 

 

 

 

 

 

essary. Be sure to replace with the

 

 

 

 

 

 

correct size fuses: two 6A fuses

 

 

 

 

 

 

for the motor and one 1A fuse for

 

 

 

 

 

 

the power supply.

 

 

 

 

 

 

 

13

I pressed the motor reverse

a.

see problem 12

 

a.

See problem 12.

 

button, but the rolls would

 

 

 

 

 

 

not turn!

 

 

 

 

 

 

 

 

 

 

 

 

14

I pressed the main roll down

a.

Is there air pressure to the

 

a.

Verify that the air supply is suffi-

 

push button, but the roll did

 

machine?

 

 

 

b.

Is there at least 20 psi on the

 

 

cient ( 100 psi).

 

not go down!

 

b.

Turn up regulator for main roll

 

 

 

gauge?

 

 

pressure.

 

 

c.

Are the e-stop push buttons

 

c.

See problem 12.

 

 

 

pressed and the kick cables reset?

d.

See problem 12.

 

 

d.

Is the machine reset?

 

e.

Reset the machine. See "Machine

 

 

 

 

 

 

Reset Procedure" on page 3-3.

 

 

 

 

 

 

 

15

I pressed the main roll up

a.

Is there air pressure to the

 

a.

Verify that the air supply is suffi-

 

push button, but the rolls did

 

machine?

 

 

 

b.

Is the machine reset?

 

 

cient ( 100 psi).

 

not go up!

 

b.

Reset the machine. See "Machine

 

 

 

 

 

 

Reset Procedure" on page 3-3.

 

 

 

 

 

 

 

16

I pressed the pull roll down

a.

Is there air pressure to the

 

a.

Verify that the air supply is suffi-

 

push button, but the rolls did

 

machine?

 

 

 

b.

Is there at least 20 psi on the

 

 

cient ( 100 psi).

 

not go down!

 

b.

Increase the pull roll air pressure.

 

 

 

gauge?

 

c.

Disconnect and reconnect air

 

 

c. Is the roll hook retracted?

 

 

pressure to the machine and

 

 

d. Are the e-stop push buttons

 

 

observe pull roll locking mecha-

 

 

 

pressed and the kick cables reset?

 

nism.

 

 

e.

Is the machine reset?

 

d.

See problem 12.

 

 

 

 

 

e.

Reset the machine. See "Machine

 

 

 

 

 

 

Reset Procedure" on page 3-3.

 

 

 

 

 

 

 

© GBC Pro-Tech 1998 October