Safety

ORCA-IV Image Transfer Laminator Operation Manual

 

 

IMPORTANT

Do not operate the image transfer laminator near water. You can be severely shocked, electrocuted or cause a fire.

DANGER

Remove and lockout power from the image transfer laminator before servicing. You can be severely shocked, electrocuted or cause a fire.

IMPORTANT

Do not use liquid or aerosol cleaners on the image transfer laminator. Do not spill liquid of any kind on the image transfer laminator. You can be severely shocked, electrocuted or cause a fire. Use only a damp cloth for cleaning.

IMPORTANT

Use only 80% (or stronger) isopropyl alcohol or a rubber cement eraser to clean the rolls. Harsh chemicals like toluene, acetone or MEK destroy the silicone covering of the rolls.

IMPORTANT

Exercise care when cleaning the rolls with80% (or stronger) isopropyl alcohol:Use only in a well ventilated area.Wear rubber gloves.Use only on cool rolls.Cleaning heated rolls can ignite the fumes.

IMPORTANT

Raise the upper main roll when the image transfer laminator is not in operation. Prolonged contact can damage the rolls.

IMPORTANT

Do not leave the top roll heater on with the roll raised. Heat builds up in a stationary roll and can damage it.

IMPORTANT

Excess pressure can damage the rolls. Always select the minimum roll pressure necessary to complete the task.

IMPORTANT

If silicone adhesive contacts the upper or lower roll, remove it IMMEDIATELY using 80 % isopropyl alcohol. It can harden within an hour and ruin the roll.

IMPORTANT

The operating environment must be free of dust,

flammable liquids and vapors. You can be injured by inhaling chemical vapors. Vapor build up or stored flammable liquids can cause a fire. Excessive dust can damage the image transfer laminator.

IMPORTANT

Do not use a knife or other sharp instrument during installation or while servicing the image transfer laminator. You can cause irreparable damage to the rolls.