Read these instructions completely and carefully.

Connect the Range to Gas

The house piping and connector used to connect the range to the main gas supply must be clean, free of metal shavings, rust, dirt or liquids (oil or water). Contaminants in the supply lines can work their way into the range manifold and cause failure of gas valves or controls and clog burners or pilot orifices.

House

Flare union

Nut

Appliance

Nut

Flare union

Range pressure

piping

adapter

 

connector

 

adapter

regulator

Safety Instructions Operating Instructions

If the range is to be connected to house piping with flexible or semi-rigid metal appliance connector, connector nuts MUST NOT be connected directly to pipe threads.

The appliance connector must be installed by using the proper flare union adapters with the connector. Cutoff valve, appliance connector and adapters are not supplied with the range. (Because solid pipe restricts moving the range, we recommend use of A.G.A. certified flexible tubing.) In Canada, flexible connectors must be single wall metal connectors no longer than 6 feet in length.

Install a manual shutoff valve in the gas line in an easily accessible location outside of the range. Be sure you know how and where to shut off the gas supply to the range.

Check for leaks. After connecting the range to gas, check the system for leaks with a liquid leak detector at all joints and connections.

Tighten all connections as necessary to prevent gas leakage in the range or supply line.

CAUTION: Do not use a flame to check for gas leaks.

Check alignment of valves after connecting the range to the gas supply to be sure the manifold pipe has not been moved. A misalignment could cause the valve knob stem to rub on the control panel, resulting in a gas leak at the valve.

Disconnect the range and its individual shut-off valve from the gas supply piping system during any pressure testing of the system at test pressures greater than 1/2 psig.

Isolate the range from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.

Care and Cleaning Installation Instructions

Checking Manifold Gas Pressure

If it should be necessary to check the manifold gas pressure, connect manometer (water gauge) or other pressure device to the top burner orifice farthest from the manifold inlet and turn burner valve on.

For an accurate pressure check have at least

2 other top burners burning. Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure.

The gas supply pressure should never be over 14 inches W.C. When properly adjusted for Natural Gas the W.C. pressure is 4 inches; for LP Gas the W.C. pressure is 10 inches. The serial plate, located under the main top in the burner box area, indicates for which type of gas your range was factory adjusted.

Troubleshooting Tips Customer Service

29

Page 29
Image 29
GE 164D3333P185-1 owner manual Connect the Range to Gas, Checking Manifold Gas Pressure

164D3333P185-1 specifications

The GE 164D3333P185-1 is a high-performance component designed for industrial applications, particularly in the field of electrical engineering. This product demonstrates a blend of advanced technology, reliability, and efficiency, which makes it a preferred choice for various sectors.

One of the standout features of the GE 164D3333P185-1 is its robust design. Constructed with durable materials, it is built to withstand challenging environmental conditions. This durability ensures that it maintains performance integrity over time, minimizing the need for maintenance and reducing downtime in industrial operations.

The component incorporates state-of-the-art technologies that enhance its functionality. It utilizes advanced sensor technology, which allows for precise monitoring and control of electrical systems. This capability is crucial in applications where accuracy and reliability are paramount. Additionally, the GE 164D3333P185-1 is equipped with innovative power management features that improve energy efficiency, leading to cost savings in operational expenses.

Another key characteristic of the GE 164D3333P185-1 is its versatility. It can be seamlessly integrated into various systems, whether in manufacturing, energy production, or commercial applications. This adaptability makes it a valuable asset in the ever-evolving industrial landscape.

The GE 164D3333P185-1 also promotes enhanced safety features. It includes built-in protection mechanisms that guard against electrical surges and faults, ensuring a safe operational environment. This attribute is particularly important for organizations that prioritize safety and risk management as part of their operational protocols.

Moreover, the ease of installation and user-friendly interface of the GE 164D3333P185-1 simplify the integration process. Technicians can efficiently set up and operate the component without extensive training, leading to quicker project turnaround times.

In summary, the GE 164D3333P185-1 is an exemplary product that showcases the best of modern engineering. With its robust design, advanced technologies, energy efficiency, safety features, and versatility, it stands as a critical component for industries looking to enhance their operational capabilities. Adopting the GE 164D3333P185-1 means investing in a future-proof solution that addresses the demands of today's dynamic industrial environments.