GE 164D3333P185-1 Surface Burner Air Shutter Adjustment, Oven Burner Air Shutter Adjustment

Models: 164D3333P185-1

1 36
Download 36 pages 12.03 Kb
Page 32
Image 32
Surface Burner Air Shutter Adjustment

Safety Instructions

Installation of the range.

Read these instructions completely and carefully.

Surface Burner Air Shutter Adjustment

Operating Instructions

The approximate height of the flame at the high or full ON position is a distinct inner blue cone of at least 3/4 inch. Turn valve knob counterclockwise 90° to the full ON position and adjust air shutter as follows:

To correct a yellow flame—Increase size of air shutter opening.

To correct a lifting, but distinct, blue flame— Decrease size of air shutter opening.

3/4

Lock screw

Air shutter

Orifice

and Cleaning

Oven Burner Air Shutter Adjustment

Customer Service Troubleshooting Tips Installation Instructions Care

The oven burner flame should be a clean, blue flame with distinct inner cones approximately 1/2 inch long. A soft, lazy flame with indistinct cones means too much gas or not enough air. A noisy lifting flame means too much air.

If adjustments are necessary:

First loosen the lock screw located at the top of the air shutter, then rotate the air shutter to the correct setting, and retighten screw.

Oven burner flame can be checked as follows (without burner baffle in place):

To correct a yellow flame—Increase size of air shutter opening.

To correct a lifting, but distinct, blue flame—Decrease size of air shutter opening.

Lock screw

Air shutter

Orifice cap

The air shutter should be set approximately 2/3 open for natural gas, and approximately full open on LP gas.

The oven burner air shutter adjustment is the same on ranges with a gas pilot or electric ignition.

Repeat steps 1 through 3 for the broil burner, if equipped, to properly adjust the broil burner flame.