5 4-Wire Power Cord Installation
WARNING: The neutral wire of the supply circuit is connected to the neutral terminal located in the center of the connector block. The power leads must be connected to the outside (brass colored) terminals. The 4th grounding lead must be connected
to the frame of the range with the grounding plate and grounding screw.
a Remove the 3 screws from the connector block.
| Remove the grounding screw and strap from the connector block middle |
b | |
| location and the screw connection to the frame of the range. |
| Insert screws through each power cord terminal ring and into connector |
c | |
| block until screw engages nut. Be certain that the center wire is connected |
| to the center screw of the connector block. Tighten screws securely. |
d Attach ground wire to the frame of the range.
Before | After |
Neutral terminal | Neutral terminal |
Grounding
plate
Ground strap
(grounding to range)
Grounding to range
Safety Information Operating Instructions Installation Instructions Troubleshooting Tips Customer Service
49