GE 8500 Series Safety, Instructions, Care and Cleaning Troubleshooting Tips Consumer Support

Models: 8500 Series

1 28
Download 28 pages 10.39 Kb
Page 5
Image 5
Temperature Limiting (Requires room air sensor kit–RAVRMS)

GEAppliances.com

Temperature Limiting (Requires room air sensor kit–RAVRMS)

Safety

Temperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. Temperature limiting is controlled by switches 1–6 on the top block

TL3 (C) (Temp. Limit 3–Cool)

TL2 (C) (Temp. Limit 2–Cool)

TL1 (C) (Temp. Limit 1–Cool)

of auxiliary controls. The first three switches are used to select the cooling limits. The next three switches are used to control the heating limits.

TL1 (H) (Temp. Limit 1–Heat)

TL2 (H) (Temp. Limit 2–Heat)

TL3 (H) (Temp. Limit 3–Heat)

Instructions

Operating Instructions

Temperature limiting during COOL mode

 

(all temperatures shown in °F)*

 

(all temperatures shown in °F)

 

UP

DOWN

Minimum

Maximum

UP

DOWN

Minimum

Maximum

NONE

1, 2, 3

60°

85°

NONE

4, 5, 6

60°

85°

1

2, 3

64°

85°

4

5, 6

60°

80°

1, 2

3

66°

85°

4, 5

6

60°

78°

2

1, 3

68°

85°

5

4, 6

60°

76°

2,3

1

70°

85°

5,6

4

60°

74°

1, 2, 3

NONE

72°

85°

4, 5, 6

NONE

60°

72°

1, 3

2

74°

85°

4, 6

5

60°

70°

3

1, 2

76°

85°

6

4, 5

60°

65°

* Not applicable to Cool-Only models

Care and Cleaning

Troubleshooting Tips Consumer Support

5

Page 5
Image 5
GE 8500 Series Safety, Care and Cleaning Troubleshooting Tips Consumer Support, Operating Instructions