Controls–dip switches.

Controls–dip switches.

GEAppliances.com

Controls–Dip Switches

The dip switch controls are located behind the front case panel, through an opening on the front of the unit.

To access the dip switches, remove the front case panel by removing the filter, taking out the four front screws, the upper two screws from the top of the panel and the shipping screws on each side, if present. (Discard the four side shipping screws, if present).

Safety Instructions

Operating

Side Controls–Dip Switches shipping screw

NOTE: The owner is responsible for setting the appropriate dip switches and connecting terminals.

Side Safety InstructionsInstructionsCare and CleaningAll Electric Heat (Heat pump models only) shipping screw

Instructions

TL3 (C) (Temp. Limit 3–Cool)

TL2 (C) (Temp. Limit 2–Cool)

TL1 (C) (Temp. Limit 1–Cool)

ALL I2R (All Electric Heat) (Heat-pump models only) FREEZ S (Freeze Sentinel)

CONST FAN (Constant ON Fan)

TL1 (H) (Temp. Limit 1–Heat)

TL2 (H) (Temp. Limit 2–Heat)

TL3 (H) (Temp. Limit 3–Heat)

No Function (Reserved for future use)

DUCT (Blower Fan)

OCCUPIED (Occupancy Sensor)

Care and Cleaning

Troubleshooting

All Electric Heat (Heat pump models only)

When this switch is enabled (UP), heat pump operation is locked out, causing the unit to provide only electric resistance heat.

Tips ALL I2R (All Electric Heat)

Tips

Consumer Support

3

Page 3
Image 3