GE 8500 Series Operating Instructions, Care and Cleaning Consumer Support Troubleshooting Tips

Models: 8500 Series

1 28
Download 28 pages 10.39 Kb
Page 4
Image 4
Operating Instructions

Safety Instructions

Operating Instructions

Care and Cleaning

Consumer Support Troubleshooting Tips

Controls–dip switches.

Freeze Sentinel (Requires room air sensor kit–RAVRMS)

When this switch is enabled (UP), it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN), the freeze sentinel is activated which automatically provides heat without user interface. This helps to prevent plumbing damage by turning the heater and fans ON at 41° F and OFF at 46° F.

Constant ON Fan

When this switch is enabled (UP), it allows the fan to run continuously.

Occupancy Sensor (Field Supplied)

When this switch is enabled (UP), it allows the unit to utilize an infrared motion sensor and a door switch for occupancy detection. This feature combined with field devices automatically cycles the unit between normal operation and a preset energy management operation.

Duct

The duct select function allows the indoor

fan to be operated at two variable fan speeds. When this switch is enabled (UP), the unit automatically selects either high or middle fan speed (for longer ductwork applications). When set in the down position, the unit is automatically operated in either the middle or low fan speed (for shorter ductwork applications).

FREEZE S (Freeze Sentinel)

CONST FAN (Constant ON Fan)

OCCUPIED (Occupancy Sensor)

DUCT (Blower Fan)

4

Page 4
Image 4
GE 8500 Series Operating Instructions, Care and Cleaning Consumer Support Troubleshooting Tips, Constant ON Fan, Duct