ANSI X3.28/SRIO DPA

GE Energy Services

CONFIGURATION GUIDE

Can't allocate rx sinks

Cause:

Not enough RAM available for the receive buffer queue to be created.

Remedy:

Reduce the amount of memory used by this or other applications in the system.

Upgrade to a larger memory model.

Can't create required exchanges. Suspending

Cause:

The system cannot create the external interface inter-process message exchange.

Remedy:

Contact the Customer Service Department to report this error.

Can't create T071 exchange

Cause:

The system cannot create the external interface inter-process message exchange.

Remedy:

Contact the Customer Service Department to report this error.

Can't get enough memory for ANSI Application. Suspending

Cause:

The system cannot retrieve enough ram for operation of the ANSI DPA.

Remedy:

Reduce the amount of memory used by this or other applications in the system.

Upgrade to a larger memory model.

Can't allocate memory for event queue. Suspending !

Cause:

The system cannot retrieve enough ram for operation of the ANSI DPA.

Remedy:

Reduce the amount of memory used by this or other applications in the system.

Upgrade to a larger memory model.

Can't open communications port

Cause:

The system has found that this port is invalid, or already in use by another process.

Remedy:

Ensure the Port configured in A071MAIN contains a valid port name.

Ensure the Port configured in A071MAIN is not in use by another application.

A071-0CG-2.02-2Restricted