ALARMS

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 42

 

 

Gravimetric Blender

 

 

 

 

 

 

 

 

ALARMS

 

 

 

 

 

 

 

 

 

Alarm-message

Description

Action to cancel alarm

 

 

 

 

 

 

Press enter

Alarm already cancelled

Press enter

 

 

 

Operator must confirm

 

 

 

 

 

 

 

 

No control voltage

No 24V control voltage present

Turn on the main-switch

 

 

 

 

or check fuses

 

 

Covers open

Security cover not present or mixerchamber

Place security-cover /

 

 

 

removed

mixer-chamber

 

 

 

 

 

 

 

Production weight

producedWeight equals produktionweight

Reset the

 

 

reached

 

producedWeight

 

 

No weighbin or

Zero weight of the weighbin is greater then

Loadcell must be

 

 

calibrate

‘maximumTareVariation’

calibrated or a tare

 

 

 

 

procedure must be done.

 

 

Parameters corrupted

The controller can’t read his parameters

Check the parameters *)

 

 

 

correctly. All parameters will be filled with

 

 

 

 

standard values.

 

 

 

Data corrupted

The controller can’t read the productiondata

Confirm *)

 

 

 

(production-screen). The data will be cleared.

 

 

 

Hopper low

The hoppersensor (optional) indicates that a

Fill hopper with material

 

 

 

hopper runs out of material.

 

 

 

 

 

 

 

 

Hopper empty

No material is dispensed so the controller

Fill hopper with material and

 

 

 

indicates that a hopper must be empty.

press the start-button.***)

 

 

Loadcell not calibrated

The controller can’t read the loadcell

Calibrate the weighbin

 

 

 

parameters correctly.

 

 

 

Loadcell overload

Weight of the weighbin is greater than the

Remove material out of

 

 

 

loadcellOverload parameter.

the weigbin.

 

 

 

 

Check in recipe the

 

 

Loadcell not stable

Weightsignal from the loadcell doesn’t fit

Press enter *) **)

 

 

 

the band.

 

 

 

 

 

 

 

 

Loadcell need

Controller needs more samples to generate a

Press enter *)

 

 

more samples

stable weight.

 

 

 

 

 

 

 

 

Loadcell boundary error

To much weight-samples doesn’t fit the band.

Press enter *)

 

Silo high

Silo supply hopper is full for several batches.

Counter will

 

 

 

(High sensor is activated)

automaticaly cleared.

 

 

 

 

 

 

 

Regrind process par

Given hoppernumbers doesn’t contain regrind

Check the regrind

 

 

conflict

or percentage

control parameters

 

 

 

 

 

 

 

Additive regrind par

Given hoppernumber doesn’t contain additive

Check the

 

 

conflict

 

AdditiveToRegind

 

 

 

 

parameters

 

 

 

 

 

 

 

 

 

 

 

Page 43