GE FGB-M05 manual Public Parameters, Init, Description

Models: FGB-M05

1 52
Download 52 pages 8.37 Kb
Page 34
Image 34
PUBLIC PARAMETERS

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 33

 

Gravimetric Blender

 

 

 

 

 

PUBLIC PARAMETERS

 

 

 

 

Parameter

Description

Init

AlarmReport

Indicates if alarm-reports must be printed.

No *)

ProductionReport

Indicates if production-reports must be printed.

No *)

 

If so the parameter interval-time must be given also.

 

Interval

Pauze (time) before printing the next production-report.

01:00.00

 

 

 

BatchReport

Indicates if batch-reports must be printed.

No *)

ProductionMode

Actual production-mode. There are three possible

CONTINUE

 

modes; CONTINUE, WEIGHT and ALARM_

 

 

WEIGHT. If the mode WEIGHT os ALARM_

 

 

WEIGHT has been selected the parameter production

 

 

Weight must also be given.

 

ProductionWeight

The FGB stops his production when the production

100 [Kg]

 

Weight is reached. (productionMode must be

 

 

WEIGHT or ALARM_WEIGHT).

 

 

 

 

DispenseMode

Actual dispense-mode. There are three possible

GRAVIMETRIC

 

modes; GRAVIMETRIC, VOLUMETRIC and

 

 

COMBINATION. If the mode COMBINATION is

 

 

chosen the parameter combinationRatio must be given.

 

 

 

 

CombinationRatio

Relation between the volumetric and gravimetric

3

 

dispenses. (one gravimetric dispense and x

 

 

volumetric dispenses).

 

 

 

 

MixMode

Actual mixermode. There are four possible modes;

PULSE

 

ON, OFF, NORMAL and PULSE. In normal-mode

 

 

the parameter mixerOnTime must be given. In the

 

 

mode pulse the parameters mixerPulseOnTime and

 

 

mixerPulseOffTime must be given.

 

 

 

 

MixerOnTime

Time the mixer is activated after the material is

10 [s]

 

dumped out of the weighbin.

 

MixerPulseOnTime

Time the mixer is activated in pulse-mode.

5 [s]

 

 

 

MixerPulseOffTime

Time the mixer is not activated in pulse-mode.

15 [s]

AdditiveToRegrind

Percentage additive to regrind which must be added.

0 [%]

Percentage 1/2

 

 

AdditiveToRegrind

Hoppernumber in which the additive is.

Hopper 5

Hopper 1/2

 

 

 

 

 

WeighbinDumpTime

Time the weighbinvalve is activated (dumping of

4 [s] 0,5 kg unit

 

material into the mixerchamber).

6 [s] 1,2,5 and

 

 

25 kg unit

 

 

 

LevelControlWaitTime

Time between the full signal of the mixerchamber

8 [s]

 

sensor and opening the mixerchamber-valve.

 

 

 

 

LevelControlDumpTime

Time between the free signal of the mixerchamber

 

 

sensor and closing the mixerchamber-valve.

1 [s]

 

 

 

*)

No = [ ], Yes = [X]