Pause

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 6

 

Gravimetric Blender

 

Pause

When the pause-command is given for a temporary stop the blender will stop after the cycle is complete.

Stop requested

The blender is operating but has received a stop-command. The stop-command will be executed at the end of a batch-cycle. This status will be replaced automatically with ‘standby’ if nothing is done. If a start-command is given during the status ‘stop requested’ the status will be ‘operate’ again.

Error

The controller has detected an error and therefore the system will stop. In a sub-menu at the operator-interface the error will be displayed. The error situation can be recovered using the <ENTER> command. The error must be solved then.

2.3Machine-mode

The controller can be in two modes: Automatic and Manual. The operator can change the mode using the menu item ‘controller’. This changing of mode is only possible while the blender has status ‘standby’.

If a controller is in Automatic-mode, the recipe will be executed without the need of an operator. This mode is used for production purposes and is only dependent on the settings ‘production-mode’.

In automatic mode the keys mentioned below mean:

F5 Start-command (start-key)

F6 Stop-command (stop-key)

F7 Pause-command

F8 Continue-command (clear pause)

After a start-command in Manual-mode one batch will be executed. After this the machine- status will be ‘standby’ again. The weighbin and mixbin-valve can be controlled manually.

In manual mode the keys mentioned below meaning:

F5 Step-command (One component of a batch)

F6 Reset-command (Back to the first component of a batch)

F7 Empty weighbin

F8 Empty mixbin