Rev. May 2001 | Page 32 | |
| Gravimetric Blender |
|
3.4.3Hardware-reactiontime
The adjustment of the number of pulses is very important for the autopulse system of the
The autopulse system does not caculate the rate in g/s but in g/puls. It calculates how many pulses he needs for an amount of material. This is why it is very important that the opening time of the pulse is not too long, because it cannot dose accurate anymore.
Standard adjustment:
Hopper | Clockpulses | Time (s) |
|
|
|
1 | 3 | 0,015 |
|
|
|
2 | 4 | 0,020 |
3 | 4 | 0,020 |
|
|
|
4 | 3 | 0,015 |
|
|
|
3.5Overview of parameters
The controller has a great number of parameters. The parameters are necessary to control the machine with all its features. The parameters are broken down into two groups; public- parameters and
3.5.1Public parameters
Below a list is given of all parameters which are attainable by the menu (F1) ‘controller / public parameters’.