3.4.3Hardware-reactiontime

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 32

 

Gravimetric Blender

 

3.4.3Hardware-reactiontime

The adjustment of the number of pulses is very important for the autopulse system of the FGB-M05. When dosing less than 8 gram of material, the GraviMaster will switch over to the autopulse system. In the hardware-reactiontime the opening time can be adjusted by increasing the clockpulses. One clockpulse is 5 ms (0,005 s).

The autopulse system does not caculate the rate in g/s but in g/puls. It calculates how many pulses he needs for an amount of material. This is why it is very important that the opening time of the pulse is not too long, because it cannot dose accurate anymore.

Standard adjustment:

Hopper

Clockpulses

Time (s)

 

 

 

1

3

0,015

 

 

 

2

4

0,020

3

4

0,020

 

 

 

4

3

0,015

 

 

 

3.5Overview of parameters

The controller has a great number of parameters. The parameters are necessary to control the machine with all its features. The parameters are broken down into two groups; public- parameters and protected-parameters. Free parameters may be changed by an operator, protected parameters may only be changed if the password is given.

3.5.1Public parameters

Below a list is given of all parameters which are attainable by the menu (F1) ‘controller / public parameters’.