❑Orifice Spuds for Convetiingto LPGas:

CONVERTING SURFACE BURNERS ON MODELS EQUIPPED WITH SEALED BURNERS (See Step 4 if range is equipped with dual burners.)

Burner Cap

 

<

 

 

 

Burner Head

 

 

 

 

 

Qi

 

.

a

1.Remove grates, burner caps and burner heads.

2.Remove burner bases by unscrewing the 3 small screws in each base. ~ burner straight out.

DO N~ disconnect the wires from the burner bases unless the cooktop needs to be raised.

3. Remove the brass orifice spud under each burner base by unscrewing spud from fitting with 7mm or 5/16” wrench (depending on the size of your spuds). Apply a 3/4” wrench to the hex on the gas inlet tube as a back-up when removing spud to prevent the aluminum tube horn twisting.

4. Install orifice spuds accordin to one of the

following diagrams (see or B ), for LP d

gas or natural gas, depending on which you are converting to.

Orifice Spuds for Convetiingto LPGas:

LP orifice spuds are in a small plastic bag packed with this Use and Care book. LP or~lce spuds have a 2-digit number and the Letter “L” on

one side. Each orifice spud will also have 1 or 2 grooves on one side, denoting the location on the range where it is to be installed.

Orifice Spuds for Convetiingto NaturaI Gas:

Natural gas or~lce spuds have a 3-digit number on one side. Each otilce spud will also have 1, 2 or 3 grooves on one side, denoting the location on the range where it is to be installed.

(continued next page)