GE JGBS16GEP, JGSS05GES, JGSS05GER, JGBS15GER Provide Adequate Gas Supply, Confect The Range To Gas

Models: JGBS02EM JGBS02PN JGBS16GEP JGBS04GPR JGBS04PR JGBS04GER JGBS04ER JGBS14GES JGBS17GER JGBS18GES JGBS06ER JGBS19GEP JGBS06ES JGBS12GER JGBS15GER JGSS05GER JGSS05GES

1 48
Download 48 pages 61.19 Kb
Page 31
Image 31
❑PROVIDE ADEQUATE GAS SUPPLY

PROVIDE ADEQUATE GAS SUPPLY

Your range is designed to operate at a pressure of 4“ of water column on natural gas or, if designed for LP gas @ropane or butane), 10” of water column. Make sure you are supplying your range with the type of gas for which it is designed. This range is convertible for use on natural or propane gas, if you decide to use this range on a different type of gas, conversion adjustments must be made by a service technician or other qualified person before attempting to operate the range on that gas.

For proper operation, the pressure of natural gas supplied to the regulator must be between 4“ and 13” of water column. For LP gas, the pressure supplied must be between 10” and 13” of water column. men checking for proper operation of the regulator, the inlet pressure must be at least 1“ greater than the operating (manifold) pressure as given above. The pressure regulator located at the inlet of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used. A flexible metal appliance connector used to connect the range to the gas supply line should have an I.D. of 1/2” and be

5 feet in length for ease of installation. In Canada, flexible connectors must be single wall metal connectors no longer than 6 feet in length.

CONFECT THE RANGE TO GAS

Shut off the main gas supply valve before disconnecting the old range and leave it off until new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.

Because hard piping restricts movement of the range, the use of an A. G.A.-certtiled flexible metal appliance connector is recommended unless local codes require a hard-piped connection. Never use an old connector when installing a new range. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.

To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.

Teflon: Registered trademark of DuPont

Gas Pipe and Electric Outlet Locations

for Models Equipped with Sealed Burners

Gas Pipe and Electric Outlet Locations for Models Equipped with Dual Burners

This area allows

installation with through-the-floor connection of pipe stub/shut-off valve.

(continued next Page)

31

Page 31
Image 31
GE JGBS16GEP, JGSS05GES manual Provide Adequate Gas Supply, Confect The Range To Gas, Gas Pipe and Electric Outlet Locations