GE JGBS02EM, JGSS05GES, JGSS05GER, JGBS15GER, JGBS12GER Ca~On Do Not Use A Fme To Check For Gas ~

Models: JGBS02EM JGBS02PN JGBS16GEP JGBS04GPR JGBS04PR JGBS04GER JGBS04ER JGBS14GES JGBS17GER JGBS18GES JGBS06ER JGBS19GEP JGBS06ES JGBS12GER JGBS15GER JGSS05GER JGSS05GES

1 48
Download 48 pages 61.19 Kb
Page 33
Image 33
CA~ON: DO NOT USE A FME TO CHECK FOR GAS ~.

1.Install a manual gas line shut-off valve in the gas line in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range.

2.Install male 1/2” flare union adapter to the 1/2” NPT internal thread elbow at inlet of regulator. On models equipped titi dud burners, install the male pipe thread end of the 1/2” flare union adapter to the 1/2” NPT internal thread at inlet of pressure regulator. Use a backup wrench on the regulator fitting to avoid damage.

men installing the range from the front, remove the 90° elbow for easier installation.

3.Install male 1/2” or 3/4” flare union adapter to the N~ internal thread of the manual shut- off valve, taking care to back-up the shut-off valve to keep it from turning.

4.Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve.

5.men all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.

CA~ON: DO NOT USE A FME TO CHECK FOR GAS ~.

men using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. men using test pressures of 1/2 psig or less to test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.

ELECIRl~L CONNECTIONS

Electrical Requiremen&

120volt, 60 Hertz, properly grounded branch circuit protected by a 15-amp or 20amp circuit breaker or time delay fuse.

Efiension Cord Cautions

Because of potential safety hazards associated with certain conditions, we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL-listed,

3-wire grounding-type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to, or greater than, the branch circuit rating.

Grounding

IMPORTN—(Please read carefilly)

FOR PERSONAL SAFETY, THIS APPLWCE MUST BE PROPERLY GROUNDED.

The power cord of this appliance is equipped with a three-prong @rounding) plug which mates with a standard three-prong grounding

 

 

wall

receptacle

PREFERRED

,

to minimize the

METHOD

 

possibility of

 

~q

electric shock

0<

hazard from

 

%,

this

appliance.

 

R

The

customer

ENSURE PROPER

should have the

GROUND EXISTS

wall receptacle

BEFORE USE

T

 

and

circuit

checked by a

qualified electrician to make sure the receptacle is properly grounded.

mere a standard two-prong wall receptacle is encountered, it is the personal responsibility and obhgation of the customer to have it replaced with a properly grounded thre~prong wall receptacle.

DO NOT, UNDER M CIRCUMSTANCES, CUT OR REMO~ THE THIRD (GROUND) PRONG FROM THE PO~R CORD.

(continued next Page)

33

Page 33
Image 33
GE JGBS02EM, JGSS05GES, JGSS05GER, JGBS15GER, JGBS12GER, JGBS06ES, JGBS19GEP, JGBS06ER Ca~On Do Not Use A Fme To Check For Gas ~