POWER SUPPLY LOCATIONS

Installation Instructions

POWER SUPPLY LOCATIONS

GAS SUPPLY:

These cooktops are designed to operate on natural gas at 4of water column pressure or on LP gas at 10of water column pressure.

ELECTRICAL SUPPLY:

These cooktops are shipped from the factory

set for natural gas. If you decide to use this

cooktop with LP gas, conversion adjustments

must be made by a service technician or

other qualified person.

The pressure regulator must be connected in

series with the manifold of the cooktop and must

remain in series with the supply line regardless

of type of gas being used.

For proper operation, the maximum inlet pressure

to the regulator must be no more than 10water

column pressure for natural gas and 14water

column pressure for LP gas.

2

2912min

3GAS SUPPLY: min

C

L

Gas pipe location

4(to clear toe kick area)

ELECTRICAL SUPPLY:Electrical outlet

12above cabinet floor (mount on side or back cabinet wall 2min. from centerline)

When checking the regulator, the inlet pressure

must be at least 1greater than the regulator

output setting. If the regulator is set for 4of

water column pressure, the inlet pressure must

be at least 5. If the regulator is set for 10of

water column pressure, the inlet pressure must

be at least 11. For ease of installation, and if local

codes permit, the gas supply line into the cooktop

should be 1/2or 3/4ID flexible metal appliance

connector, three to five feet long.

NOTE: Purchase a new flexible line. DO NOT USE

AN OLD PREVIOUSLY USED LINE.

Make gas connection through rear wall, or on

cabinet floor at rear, as illustrated.

The built-in gas downdraft cooktop features pilotless electric ignition for energy savings and reliability. It operates on a 120-volt, 60-Hz power supply. A separate circuit, protected by a 15-amp time-delay fuse or circuit breaker, is required.

A properly grounded 3-prong receptacle should be located within reach of cooktop’s four foot power cord.

IMPORTANT: (Please read carefully.) FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

The power cord of this appliance is

equipped with a three-prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and has correct polarity.

Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.

Do Not, Under Any Circumstances, Cut Or Remove The Third (ground) Prong From The Power Cord.

Do not use an extension cord.