Power Supply

Installation Preparation

Stainless Steel Interior Dishwashers

Power Supply

WARNING

FOR PERSONAL SAFETY:

REMOVE HOUSE FUSE OR OPEN

 

 

CIRCUIT BREAKER BEFORE BEGINNING

 

INSTALLATION.

DO NOT USE AN EXTENSION CORD OR

ADAPTER PLUG WITH THIS APPLIANCE.

FOLLOW NATIONAL ELECTRICAL

CODES OR PREVAILING LOCAL CODES

AND ORDINANCES.

 AVERTISSEMENT AVERTISSEMENT

SÉCURITÉ

IL FAUT ENLEVER LE FUSIBLE DE LA

MAISON OU OUVRIR LE DISJONCTEUR

AVANT DE COMMENCER

L’INSTALLATION.

IL NE FAUT PAS UTILISER DE

18"

Receptacle

18" Electrical Requirements: Location

Area

6" 6"Grounding Instructions:

Alternate

Receptacle

Location

1-1/2" Dia. Hole (Max.)

3"

2"Cabinetfrom

2" 24" from Wall

Ground

Black

White

Cabinet Preparation & Wiring: RALLONGE NI D’ADAPTATEUR DE FICHE AVEC CET APPAREIL. IL FAUT RESPECTER TOUS LES CODES D’ÉLECTRICITÉ NATIONAUX OU LES CODES ET RÈGLEMENTS LOCAUX EN VIGUEUR.

Electrical Requirements:

These dishwashers must be supplied with a 120 volt, 60 Hz power supply with an indi- vidual, properly grounded branch circuit, protected by a 15 or 20 amp fuse or circuit breaker or time delay fuse.

Wiring must be 2 wire with ground.

If electrical supply does not meet the above requirements, call a licensed electrician before proceeding.

Grounding Instructions:

This appliance must be either connected to a grounded-metal permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and be connected to the equipment-grounding terminal or lead on the appliance.

Cabinet Preparation & Wiring:

Wiring may enter from either side, the rear, or from the floor within the shaded area shown.

Cut hole 1-1/2” max. diameter within the shaded area to admit the electrical cable or power cord. The hole must be free of sharp edges. If the cabinet wall partition is metal, the edge of the hole must be covered with a rubber protector.

Electrical Connections:

The electrical connection is on the right side of the dishwasher.

For cable direct connections, the cable must be routed as illustrated. The cable must extend forward a minimum of 24” from the rear wall.

For power cord connections, install a

3-prong type receptacle in the rear wall of sink cabinet next to the dishwasher. Install the receptable at least 6” and not more than 18” from the dishwasher opening. The receptacle should be at least 6” and not more than 18” off the floor.

Allow approximately 3” between cable and adjacent cabinetry.

Electrical Connections: WARNING