7SIZE AND CUT DUCT PIECE

Hold upper air deflector with duct connector against the ceiling.

Measure from the bottom

 

of the air deflector to the

 

top of the hood as

Measure

 

shown. Reduce that

 

length

Duct

dimension by 1to

 

facilitate installation.

 

length

 

 

The duct will cover

 

 

and overlap the deflector

 

and the hood outlets.

 

Deflector

Cut the duct piece to size and slip onto the bottom of the deflector.

Place the assembled deflector

and duct over the exhaust outlet.

Hold the assembly against the duct bracket.

Drive 4 screws into the bottom of the deflector and into the bracket.

Use duct tape to seal duct to the deflector and at the exhaust outlet.

8 CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.

AVERTISSEMENT :

Si la maison n’est pas câblee avec deux fils et un fil de terre, l’installateur doit installer un fil de terre. Quand les fils sont en aluminium, il faut prendre soin d’utiliser des connecteurs aluminium à cuivre avec une pâte antioxydante approuvée par U.L.

Remove junction box cover and knockout on the left side.

Knockout

J-Box cover

Secure the house wiring to the junction box with a strain relief.

House wiring

J-Box cover

Connect white leads to branch circuit white lead.

Connect black leads to branch circuit black lead.

Connect green/yellow leads to branch circuit green lead or bare ground lead.

Secure all connections with wire nuts on each electrical connector.

Push wires into junction box and replace cover. Be sure wires are not pinched.

Secure J-Box cover with original screw.