Installation Preparation
DETERMINE INSTALLATION HEIGHT
•Telescopic duct covers are provided to conceal the ductwork running to the ceiling.
•This hood can be installed for recirculating operation. No kits required.
|
|
|
|
NOTE: Measure |
|
|
|
installation height |
|
|
|
|
| ||
from the cooking |
| 24” Min. | |
surface to the outer |
| 30” Max. | |
glass portion of the |
|
|
|
|
| ||
hood. |
|
|
|
|
|
|
|
|
|
|
|
36” Min.
The vent hood must be installed 24″ min. and
30″ max. above the cooking surface. The hood installation height, from the cooking surface to the bottom of the hood, depends upon ceiling height.
ACCESSORIES:
•Order ZX90010 accessory for ZV900 wall mount hood to reach ceiling heights between 9′ 6″ and 10′ 5″. This accessory contains one 40″ long duct cover.
Wall Mount ZV900
Installation Heights
Actual |
| *Possible |
|
| |
Ceiling | *Possible VENTED | RECIRCULATING | |||
Height | Installation Height | Installation Height | |||
|
|
|
|
| |
7′ 11″ | 24″ to 26″ | 24″ to 26″ |
|
| |
|
|
|
|
| |
8′ 0″ | 24″ to 27″ | 24″ to 27″ |
|
| |
|
|
|
|
| |
8′ 1″ | 24″ to 28″ | 24″ to 28″ |
|
| |
|
|
|
|
| |
8′ 2″ | 24″ to 29″ | 24″ to 29″ |
|
| |
|
|
|
|
| |
8′ 3″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
8′ 4″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
8′ 5″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
8′ 6″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
| SUPPLIED |
| |
8′ 9″ | 24″ to 30″ | 24″ to 30″ |
| ||
8′ 7″ | 24″ to 30″ | 24″ to 30″ |
|
| |
8′ 8″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
8′ 10″ | 24″ to 30″ | 25″ to 30″ |
|
| |
|
|
|
|
| |
8′ 11″ | 24″ to 30″ | 26″ to 30″ |
|
| |
|
|
|
|
| |
9′ 0″ | 25″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 1″ | 26″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 2″ | 27″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 3″ | 28″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 4″ | 29″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 5″ | 30″ | 25″ to 30″ |
|
| |
|
|
|
|
| |
9′ 6″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 7″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 8″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
9′ 9″ | 24″ to 30″ | 24″ to 30″ | ZX90010 |
| |
|
|
|
| ||
9′ 10″ | 24″ to 30″ | 24″ to 30″ | |||
|
| ||||
|
|
|
|
| |
9′ 11″ | 24″ to 30″ | 24″ to 30″ | ACCESSORY |
| |
|
|
|
| ||
10′ 2″ | 25″ to 30″ | 24″ to 30″ | |||
10′ | 24″ to 30″ | 24″ to 30″ |
|
| |
10′ 1″ | 24″ to 30″ | 24″ to 30″ |
|
| |
|
|
|
|
| |
10′ 3″ | 26″ to 30″ | 25″ to 30″ |
|
| |
|
|
|
|
| |
10′ 4″ | 27″ to 30″ | 26″ to 30″ |
|
| |
|
|
|
|
| |
10′ 5″ | 28″ to 30″ | 27″ to 30″ |
|
| |
|
|
|
|
|
*Based on 36″ countertop height.
7