GE ZVC30, ZVC48 ZVC42, 39-1/2″, 38-3/4″W x 13-3/16″D, Design Information, Product Dimensions

Models: ZVC30 ZVC36 ZVC48 ZVC42

1 68
Download 68 pages 13.2 Kb
Page 7
Image 7
ZVC42

 

Design Information

PRODUCT DIMENSIONS

 

ZVC42

Dimensions and Specifications (in inches)

 

Outside Dimensions

 

39-1/2

*Opening

14

The custom canopy must be sized to fit the insert sleeve. Construct the canopy with an opening that is:

38-3/4W x 13-3/16D

The opening must be constructed of 3/4thick material to allow the sleeve locking clips to engage.

The Supplied Liner

1/2

7/8

40-1/2

 

7-1/2

1/2

4

21-1/4

Front side

 

The stainless steel liner is shipped with each hood insert . This non-combustible liner protects the underside of the canopy.

Custom Liner

If you are not using the supplied liner, you may construct a custom non-combustible liner. Use the supplied liner as a template. The opening must be 38-3/4W x 13-3/16D.3/4thick material must surround the opening to allow the sleeve locking clips to engage. The insert sleeve inside the cabinet should be positioned 1/2from the rear wall so that the center of the 8duct is 5-1/2from the rear wall.

The Insert Sleeve

1339-1/2″38-3/4″W x 13-3/16″D29-1/2

 

14

Front side

1/2

 

38-1/2

13

 

1/2

A 1/2wide flange surrounds the outside edge of the insert sleeve.

Remote Location for the Control

The control may be removed from the hood and installed into a wall or countertop. A 30-ft . length of wire is supplied to accommodate most installations. A blanking plate covers the opening when the controls are removed.

The overall size of the control is 4-1/4wide and 2-1/4deep.

3-11/16

 

 

 

 

 

Control cutout

 

 

 

 

 

1-11/16

 

 

 

 

 

 

 

 

 

 

 

 

 

We recommend that the cutout in granite or other hard surfaces be made before the countertop is installed.

7

Page 7
Image 7
GE ZVC30 ZVC42, 39-1/2″, 38-3/4″W x 13-3/16″D, Design Information, Product Dimensions, Outside Dimensions, Custom Liner