Advance Planning
DUCT FITTINGS
This Hood Must Use an
8″ Round Duct. It Can
Transition to a
Use this chart to compute maximum permissible lengths for duct runs to outdoors.
NOTE: Do not exceed maximum permissible equivalent lengths!
Maximum duct length: 100 foot for range hoods.
Flexible ducting:
If flexible metal ducting is used, all the equivalent feet values in the table should be doubled.
The flexible metal duct should be straight and smooth and extended as much as possible.
DO NOT use flexible plastic ducting.
NOTE: Any home ventilation system, such as a ventilation hood, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE.
|
|
|
| Total |
|
| Equivalent | Quantity | Equivalent |
Duct Piece | Dimensions | Length* | Used | Length |
| Round, | 1 ft . |
|
|
| straight | (per foot |
|
|
|
| length) |
|
|
| 1 ft . |
|
| |
| straight | (per foot |
|
|
|
| length) |
|
|
| 90° elbow | 17 ft . |
|
|
|
|
|
| |
| 45° elbow | 10 ft . |
|
|
|
|
|
| |
|
|
|
| |
| 90° elbow | 43 ft . |
|
|
|
|
|
| |
| 45° elbow | 26 ft . |
|
|
|
|
|
| |
| 90° flat elbow | 102 ft . |
|
|
| 8″ round to |
|
|
|
| 2 ft . |
|
| |
|
|
|
| |
| round transition | 5 ft . |
|
|
| 8″ round |
|
|
|
| to |
|
|
|
| transition 90° elbow | 6 ft . |
|
|
|
|
|
| |
| round transition 90° elbow | 13 ft . |
|
|
| Round |
|
|
|
| wall cap |
|
|
|
| with damper | 32 ft . |
|
|
|
|
|
| |
| with damper | 75 ft . |
|
|
| Round |
|
|
|
| roof cap | 44 ft . |
|
|
*Actual length of straight duct plus duct fitting
equivalent . Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation Total Duct Run Engineering and reflect requirements for good
venting performance with any ventilation hood.
10