Giantec tracer2000 manual P/T/Z Setting, Pin Assignment of COM2, Cable Connection

Models: tracer2000

1 39
Download 39 pages 39.16 Kb
Page 26
Image 26

tracer2000 Network DVR Hardware User’s Manual

3.2P/T/Z Setting

The P/T/Z Setting complies with LILIN or PELCO. Protocol has been previously attached to the COM ports. You may control the camera via arrow buttons. In this case, you don’t need to buy dedicated P/T/Z controller.

3.3Pin Assignment of COM2

Connect 9 PIN Female D_SUB to COM2 (Pin defines as below).

1 5

6 9

RS232 / RS422 / RS485 Connector (COM2)

Pin No.

RS232

RS422

RS485

1

DCD

TX-

DATA-

2

RX

TX+

DATA+

3

TX

RX+

 

4

DTR

RX-

 

5

GND

GND

GND

6

DSR

RTS-

 

7

RTS

RTS+

 

8

CTS

CTS+

 

9

RI

CTS-

 

Note: Please setup mode type by JP3.

3.4Cable Connection

Camera input jack to COM2 for PIH-7000/7600. For example:

3.5Jumper 3 Setting of COM2

The system default of COM2 is RS485. Adjust jumper JP3 in system for RS422, RS232 signals as show below.

JP3

1

2

17 18

RS485

JP3 JP3

1

2

1

2

17

18

17

18

RS422 RS232

Version 3.1

Page 18 of 31

Page 26
Image 26
Giantec tracer2000 P/T/Z Setting, Pin Assignment of COM2, RS232 / RS422 / RS485 Connector COM2 Pin No, Cable Connection