GM JDP40 manual Care, Prepare for Electrical Connection

Models: JDP40

1 32
Download 32 pages 10.57 Kb
Page 23
Image 23

Read these instructions completely and carefully.

Prepare for Electrical Connection

This appliance is manufactured with a neutral (white) power supply wire and a cabinet-connected green (or bare copper) grounding wire.

Connect the appliance cable to the junction box through the U.L.-listed conduit connector. Complete electrical connection according to local codes and ordinances. (For preferred junction box location, see Step 1.)

NOTE: Do not use a power cord kit for connection to electrical supply.

WARNING: IMPROPER

CONNECTION OF ALUMINUM HOUSE WIRING TO COPPER LEADS CAN RESULT IN A SHORT CIRCUIT OR FIRE. USE ONLY CONNECTORS DESIGNED FOR JOINING COPPER TO ALUMINUM, AND FOLLOW THE MANUFACTURER’S RECOMMENDED PROCEDURE CLOSELY.

NOTE TO ELECTRICIAN: The armored cable leads supplied with this appliance are UL-recognized for connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.

Safety Instructions

 

Operating Instructions

 

Care and

Electrical Connection

Where local codes permit connecting the cabinet-grounding conductor to the neutral (white) junction box wire (see illustration below):

A. Disconnect the power supply.

B.Connect together the 3 wires: bare copper and white appliance cable wires and the neutral (white) wire in the junction box.

C.Connect the 2 black wires together, then the two red wires together.

Cable from

Power Supply

Black

RedWires

Wires

White

 

Wires

Junction

 

 

Box

Bare Wire

U.L.-listed

 

Conduit

 

Connector

 

Cable from

 

Range

GROUNDED NEUTRAL

When connecting to a 4-wire electrical system, when installing in a mobile home, or when local codes DO NOT permit connecting the cabinet- grounding conductor to the neutral (white) junction box wire (see illustration below):

A. Disconnect the power supply.

B.Separate the bare copper and white wires.

C.Connect the white appliance cable wire to the neutral (white) wire in the junction box.

D.Connect the 2 black wires together, then the two red wires together.

E.Connect the grounding wire (bare copper) to the grounding wire in the junction box.

 

Cable from

Junction

Power Supply

 

Box

 

 

White

Red

Wires

Wires

 

 

Black

 

Wires

Bare Wires

 

 

U.L.-listed

 

Conduit

 

Connector

Cable from

Range

4-WIRE ELECTRICAL SYSTEM

23

 

Cleaning

 

 

 

 

Instructions

Installation

 

 

 