Direct Immersion Setup (Alternate Spray Method)

1. Set AllControl to OFF.

ti9168a

2.Push down on bend of handle and pivot 90°. Remove cover.

ti9290a

ti9291a

3.Use inlet screen handle to unscrew and remove inlet screen from hopper.

ti9302a

4.Unclip drain tube from side of hopper.

ti9828a

Getting Started

7.Unscrew suction tube fitting from hopper elbow

(b).

b ti9379a

8.Install inlet screen into end of suction tube.

ti9824a

9. Engage gun trigger lock.

ti8923a

10.Unscrew tip and guard assembly from gun.

ti9204a

5.Replace hopper cover and return handle to locked position.

6.Stand sprayer upright in immersion spray position.

ti9294a

11.Uncoil hose and connect one end to gun. Use two wrenches to tighten securely.

ti9203a

12.Connect other end of hose to sprayer. Use two wrenches to tighten securely.

ti9375a

If hose is already connected, make sure con- nections are tight.